FLOOR CLEARANCE

The gas log heater must be installed at least 1

3

/

8

" above any combustible flooring material, such as carpeting or

tile, which is closer than 14" to the base of the fireplace. The minimum distance must be maintained from the top

surface of carpeting, tile, etc. Figure 10

OR

The gas log heater may be installed nearer to the floor if a minimum of 14" of noncombustible material such as

slate or marble is installed between the base of the fireplace and the combustible flooring. Figure 11

1

3

/

8

" Minimum

FP2003
min clear comb floor

Heater in

Fireplace or

Firebox

Combustible

Material

FP2003

Figure 10 - Minimum Clearance above Combustible Flooring

Figure 11 - Minimum Clearance above Combustible Flooring with

Noncombustible Material Installed at Base of Fireplace