PLACEMENT IN A FIREPLACE wITh A RESTRICTIvE BARRIER

IMPORTANT INFORMATION FOR ThE INSTALLATION OF ThIS GAS LOG SET

The following are guidelines for placing a gas log set in a fireplace that has a restrictive barrier along the bottom

front opening of the fireplace. Some examples of barriers are glass/screen door frames and sunken/recessed

fireplaces.

Glass door frames

with adjustable louvers

should have the louvers

fully open while the unit

is in operation.

Height of restrictive barrier caused

by glass door frames, recessed

fireplaces, etc. from the base or

bottom surface of the unit. (refer

to table).

The log set should be placed against

or as near as possible to the rear wall

of the fireplace/firebox.

Depth of fireplace/firebox.

(refer to table).

Figure 3 - Reference Drawing of the MJ27 Log Set in an Enclosure

NOTE: Noncombustible material such as refractory brick may be used to line the floor of the fireplace

in order to raise the height of the gas log set in relation to a restrictive barrier. If the unit is raised, the

minimum height dimension listed in the homeowner’s manual must not be exceeded.
NOTE: If the log set is equipped with a remote receiver, a restrictive barrier may reduce the battery life by

increasing the ambient temperature inside the fireplace. Placement of the receiver outside of the fireplace

will extend the battery life.

Height of Restriction (X)

Minimum Depth of Fireplace/Firebox

No restriction

14"

0 to 1

1

/

2

"

17"

From 1

1

/

2

" to 3"

17"

Greater than 3"

ANY BARRIER GREATER THAN THREE INCHES (3") PLACED IN FRONT OF

THE GAS LOG SET IS NOT RECOMMENDED BY THE MANUFACTURER.

Barriers such as the bottom of a glass door frame placed in front of a gas log set can

change the air flow characteristics of the fireplace which in turn can cause the unit to

overheat and malfunction.

W

ARNING

Anytime there is a restrictive

barrier of more than 1

1

/

2

", the

remote receiver should be

located outside the firebox.

NOTE