Installing vented applications, Warning – Monessen Hearth MJ27NR User Manual
Page 18
18
86D0024
FP2006
secure to floor
INSTALLING vENTED APPLICATIONS
PLACING AND SECuRING APPLIANCE
ASSEMBLY PROCEDuRE:
1. Center the gas log unit on the fireplace or firebox. Make certain the front of the burner sits
inside the front edge of the fireplace or firebox.
2. Anchor holes are located on the right and left sides of the unit. After centering the burner cor-
rectly, mark the hole positions on the fireplace/firebox floor. Drill two (2) 5/32" diameter holes
approximately 1
1
/
2
" deep.
3. Anchor the burner to the fireplace/firebox floor using the screws provided. Figure 13
Proper installation of the heater is essential to prevent any movement of the gas logs and
controls during operation.
Figure 13 - Secure Heater to Floor of Fireplace/Firebox
Screw
Anchor Hole
Screw
W
ARNING
You must secure the gas log heater to the fireplace floor. If not, the entire unit may move
when you adjust the controls. Movement of unit may cause shifting of the gas logs which
leads to sooting and improper burning. Grate movement could cause a gas leak.
Special care is required if you are installing the unit into a sunken fireplace. You must raise
the fireplace floor to allow access to gas log controls. This will insure adequate air flow
and guard against sooting. Raise the fireplace floor using noncombustible materials, as
described in Placement in a Fireplace with Restrictive Barrier on Page 10.
FP2006