IMPORTANT SAFETY INFORMATION

continued from page 3

15. This is an unvented gas-fired heater. It uses air

(oxygen) from the room in which it is installed. Pro-

visions for adequate combustion and ventilation air

must be provided. See page 8.

16. Keep room area clear and free from combustible

materials, gasoline and other flammable vapors and

liquids.

17. Unvented gas heaters are a supplemental zone

heater. They are not intended to be the primary

heating appliance.

18. Unvented gas heaters emit moisture into the living

area. In most homes of average construction, this

does not pose a problem. In houses of extremely

tight construction, additional mechanical ventilation

is recommended.

19. During manufacturing, fabricating and shipping,

various components of this appliance are treated

with certain oils, films or bonding agents. These

chemicals are not harmful but may produce annoying

smoke and smells as they are burned off during the

initial operation of the appliance; possibly causing

headaches or eye or lung irritation. This is a normal

and temporary occurrence.

The initial break-in operation should last four hours

to properly cure logs and rock wool, with the burner

at the highest setting. Provide maximum ventilation

by opening windows or doors to allow odors to dis-

sipate. Any odors remaining after this initial break-in

period will be slight and will disappear with continued

use.

20. Input ratings are shown in BTU per hour and are for

elevations up to 2,000 feet. For elevations above

2,000 feet, input ratings should be reduced 4 percent

for each 1,000 feet above sea level. Refer to the

National Fuel Gas Code.

21. The appliance and its appliance main gas valve must

be disconnected from the gas supply piping system

during any pressure testing of that system at test

pressures in excess of 1/2 psig (3.5 kPa).

22. The appliance must be isolated from the gas supply

piping system by closing its equipment shutoff valve

during any pressure testing of the gas supply piping

system at test pressures equal to or less than 1/2

psig (3.5 kPa).

23. Do not use this room heater if any part has been

under water. Immediately call a qualified service

technician to inspect the room heater and to replace

any part of the control system and any gas control

which has been under water.

24. This appliance must not be used with glass doors

in the closed position. This can lead to pilot outages

and severe sooting outside the fireplace.

25. Never burn solid fuels in a fireplace where a unvented

room heater is installed.

26. Always have a fireplace screen in place when the

appliance is in operation and, unless other provi-

sions for combustion air are provided, the screen

must have an opening(s) for induction of combustion

air.

Never connect unit to private (non-

utility) gas wells. This gas is commonly

known as wellhead gas.

W

ARNING

Massachussetts resiDents only:

Please refer to Pages 40 & 41 for

additional information.