Marathon monitors inc, Configuration parameter tables – Marathon Computer AACC 2000 User Manual
Page 70
Marathon Monitors Inc.
AACC 2000 Carbon Nov. 1, 1997
70
CONFIGURATION PARAMETER TABLES
Name
Description
Values
Meaning
inSt
inSt
Instrument configuration
ZrFn
Instrument Function
Carb
% Carbon
CtrL
Control type
Pid
PID control
On.OF
On/off control
VP
Boundless motorised valve
control - no feedback
required
VP b
Bounded motorised valve
control - feedback required
tYPE
Instrument USE
ctrL
Mon
Controller
Monitor
Act
Control action
rEv
Reverse acting
dir
Direct acting
CooL
Type of cooling
Lin
Linear
oiL
Oil (50mS minimum on-
time)
H2O
Water (non-linear)
FAn
Fan (0.5S minimum on-
time)
ProP
Proportional only to error
on.OF
On/off cooling
ti.td
Integral & derivative
SEc
Seconds, OFF to 9999
time units
min
Minutes, OFF to 999.9
m-A
Front panel Auto/Man button
EnAb
Enabled
diSA
Disabled
r-h
Front panel Run/Hold button
EnAb
Enabled
diSA
Disabled
PwrF
Power feedback
on
On
OFF
Off
Fwd.t
Feed forward type
none
None
FEEd
Normal feed forward
SP.FF
Setpoint feed forward
PV.FF
PV feed forward
Sbr.t
Sensor break output
Sb.OP
Go to pre-set value
HoLd
Freeze output
FOP
Forced manual output
no
Bumpless Auto/Manual
transfer
trac
Returns to the Manual
value that was set when
last in Manual mode
Step
Steps to forced output
level. Value set in ‘
FOP’ of
‘
op-List’ in Operator
Level
bcd
BCD input function
none
prog
sp
Not used
Select program number
Select setpoint number