Marathon monitors inc – Marathon Computer AACC 2000 User Manual
Page 41

Marathon Monitors Inc.
AACC 2000 Carbon Nov. 1, 1997
41
Name
Description
SP
SP
Setpoint list
SSEL
Select
SP 1 to SP16, depending on configuration
SP 1
Setpoint one value
SP 2
Setpoint two value
SP L
Setpoint 1 low limit
SP H
Setpoint 1 high limit
SP2.L
Setpoint 2 low limit
SP2.H
Setpoint 2 high limit
SPrr
Setpoint Rate Limit
Hb.ty
Holdback Type for setpoint rate limit (
OFF, Lo, Hi, or bAnd)
iP
iP
Input list
FiLt
IP1 filter time constant (0.0 - 999.9 seconds).
FLt.2
IP2 filter time constant (0.0 - 999.9 seconds).
PV.ip
Selects ‘
ip.1’ or ‘ip.2’
FLt.3
DC input Filter Time Constant
CAL
User Calibration Enable
OFS.1
simple offset
OFS.2
PV2 simple offset
mV.1
ADC Converter millivolts
mV.2
ADC Converter millivolts PV2
mV.3
Second PV millivolts input
CJC.1
IP1 cold junction temp. reading
CJC.2
IP2 cold junction temp. reading
Li.1
IP1 linearised value
Li.2
IP2 linearised value
Li.3
DC Input 3
PV.SL
Current Input or Inputs used for PV