beautypg.com

Signature command system – Monessen Hearth HDV500NV/PV User Manual

Page 51

background image

56D3048

51

HDV Series Direct Vent Gas Fireplace

tRouBleSHootING

OPERATION 

Install batteries and/or 
plug in the AC board 

Flip the master switch 
(rocker switch) to the  
ON position 

Press the ON button on 
the Command Center 

FAULT 

No beep in about 
8 seconds 

No beep 
or 
no sound from the 
valve indicating pilot 
solenoid open 

No sparking on  
the pilot 

Sparking doesn’t  
continue 

Pilot doesn’t light 

Main burner doesn’t  
light 

DIAGNOSIS 

Make sure 
Command 
Center and 
the control 
board are 
connected by 
a 2 feet or 15 
feet cable 

Check NG/LP 
conversion cap 
and control  
board  
connections 

Check pilot 
connections 

The Control Board is having interference from the 
surrounding metal (Ground) 

Check gas supply 

Go through  

Battery polarity wrong? 

LED on the Command 
Center does not show 
solid green? 

The 5-pin connector on 
the AC board broken or 
bent? 

AC plug is plugged to 
AC mains? 

Battery voltage low? 

Using 
battery? 

Check valve 
connections 

Check power 
supply (go 
through       ) 

Check 
grounding 

Go through 

Go through  C 

The sensor on the pilot  
is not in the flame  
(pilot flame too small)? 

ACTION 

Re-install batteries 

Change batteries 

Plug the AC plug to  
AC mains 

Repair or replace the  
AC Board 

Replace the AC Board 

Replace the Control  
Board or  
Command Center 

Sparking is happening 
elsewhere (under the 
pilot), re-install/replace 
the pilot 

Re-install the Control  
Board, move it around 
or change the 
Control Board 

Sparking is not in the  
path of gas flow, adjust  
sparker position or  
replace the pilot 

Adjust sensor position  
or replace the pilot 

After the beep 

FP1911 
troubleshoot sc 
8/08 

SIGNAtuRe CoMMAND SySteM