HDV Series Direct Vent Gas Fireplace

3

56D3048

APPRoVeD leAK teStING MetHoD
You may check for gas leaks with the following
methods only:
• Soap and water solution
• An approved leak testing spray
• Electronic sniffer

NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.

1. Depress and turn knob counterclockwise

to pilot position.

. Depress fully and hold pilot gas knob. Depress piezo

ignitor as many times as needed to ignite the pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to
burn.

If the pilot does not stay lit, repeat steps 1 and .

Figure 45 -
Pilot Position

Check for gas leaks in each of the following locations:
• Pipe from the gas supply line connection to the gas valve
• Burner connections

• Field made joints / gas shutoff valve

• Pilot

• Factory made joints

• Each joint or connection

• All joints on valve and control body

lIGHtING PIlot FoR tHe FIRSt tIMe - MIllIVolt

lIGHtING PIlot - MIllIVolt

W

ARNING

If using a soap and water solution
to test for leaks, Do Not spray
solution onto control body.

DANG

e

R

Never check for gas leak
with open flame!

PILOT

OF

   

   

 P

IL

O

    ON

FP1935
control knob pilot

oPeRAtING INStRuCtIoNS - MIllIVolt