Operational check for the remote control, Dct3080 installation manual – Motorola DCT3080 User Manual
Page 41
DCT3080 Installation Manual
35
Code Description
When Error Occurs
Action Required
Eb
07
Object failed
validation
After software object
download complete and FP is
displayed
After a successful software
object download and the
terminal is reset
Contact the headend
operator
No action required
because the terminal
repeats the software
object download
Eb
08
Reserved
None
Eb
09
Check failed
Reset within two minutes of a
complete software object
download
No action required
because the terminal
repeats software
object download
process
Eb
10
SUDB
recreation
After plugging the terminal
into an electrical outlet to
begin the boot cycle
None
Eb
11
Failed to lock
OOB frequency
After cycling twice through the
OOB frequencies (LED then
displays Eb 02, indicating
the software object download
was unsuccessful.)
Ensure proper cable
connections
Eb
12
No COAC
message
received
After cycling twice through the
OOB frequencies (LED then
displays Eb 02, indicating
the software object download
was unsuccessful.)
Contact headend
operator
Eb
13
No DLC
message
received
After cycling twice through the
OOB frequencies (LED then
displays Eb 02, indicating
the software object download
was unsuccessful.)
Contact headend
operator
Eb
14
Bad object type
or class
After the LED displays dl,
indicating failed during
attempted download
Contact headend
operator
Eb15 No matching
After cycling twice through the Contact headend