34
When the LED display is blank, the terminal is ready for initialization
and service authorization using the addressable controller. Verify that
the terminal is powered up or reset within two minutes of a
completed download.
Boot Cycle Error Codes
If hardware or software problems occur, the terminal displays error
codes on the LED display.
125H
Table 2-5 lists error codes that can occur
during boot cycle startup:
Table 2-5
Boot cycle error codes
Code Description
When Error Occurs
Action Required
Eb
01
Object failed
validation
After the LED displays dl,
indicating validation check
failed
Contact headend
operator
Eb
02
Download
time-out
After cycling twice through the
OOB frequencies
None
Eb
03
Flash erase
failed
After software object
download complete and EF is
displayed
Replace the terminal
Eb
04
Flash
programming
failed
After software object
download complete and FP is
displayed
Contact headend
operator
Eb
05
Invalid DLC
frequency
After the LED displays dl,
indicating validation check
failed
Contact headend
operator
Eb
06
Hardware
initialization
failed
After plugging the terminal
into an electrical outlet to
begin the boot cycle
Replace the terminal