Boot cycle, Dct3080 installation manual – Motorola DCT3080 User Manual
Page 38
DCT3080 Installation Manual
32
Boot Cycle
After connecting the proper cabling to the DCT3080, plug the power
cord into the DCT3080 and electrical wall outlet. Begin performing the
boot cycle procedure:
After a few moments, the LED displays HUNT and then FR 1.
The DCT3080 searches for the headend out-of-band (OOB)
frequency carrier. If the OOB frequency is not set to 75.25 MHz, the
LED flashes FR 1 and then flashes FR 2. This searching process
repeats until the correct OOB frequency is found and the required
message for the DCT3080 model is acquired.
The LED displays and OOB frequencies are:
Table 2-4
LED displays and OOB frequencies
Display Frequency Description
dl
N/A
OOB network download in progress
EF
N/A
Erasing Flash memory
FP
N/A
Flash memory is being programmed
____
N/A
Network download complete
Hunt
N/A
Hunting for OOB frequency
FR 1
75.25
MHz
Attempting to lock on frequency 1
FR 2
104.20
MHz
Attempting to lock on frequency 2
FR 3
72.75
MHz
Attempting to lock on frequency 3
FR 4
92.25
MHz
Attempting to lock on frequency 4
FR 5
98.25
MHz
Attempting to lock on frequency 5
FR 6
103.75
MHz