11-2. MUZ-GE18NA MUY-GE18NA

NOTE:

Turn OFF power supply before disassembling.

OPERATING PROCEDURE

PHOTOS

1. Removing the cabinet

(1) Remove the screws of the service panel.
(2) Remove the screws of the top panel.
(3) Remove the screw of the valve cover.
(4) Remove the service panel.
(5) Remove the top panel.
(6) Remove the valve cover.
(7) Disconnect the power supply and indoor/outdoor connect-

ing wire.

(8) Remove the screws of the cabinet.
(9) Remove the cabinet.
(10) Remove the screws of the back panel.
(11) Remove the back panel.

Photo 1

Photo 2

Screws

of the

cabinet

Screws

of the

back

panel

Screw of the top panel

Screws of the cabinet

Screws

of the

cabinet

Screw

of the

valve

cover

Screw

of the

service

panel

Screw of the top panel

Screws of

the back

panel