3specification – MITSUBISHI ELECTRIC MUY-GE09NA User Manual
Page 4
![background image](/manuals/116157/4/background.png)
4
Outdoor unit model
MUZ-GE09NA MUY-GE09NA
MUZ-GE12NA MUY-GE12NA
Capacity
Rated (Minimum~Maximum)
Cooling 1
Btu/h
9,000
( 3,800 ~ 12,200 )
9,000
( 3,800 ~ 12,200 )
12,000
( 3,800 ~ 13,600 )
12,000
( 3,800 ~ 13,600 )
Heating 47 1
Btu/h
10,900
( 4,500 ~ 14,100 )
—
14,400
( 5,500 ~ 18,100 )
—
Capacity
Heating 17 2
Btu/h
8,700
—
11,200
—
Power consumption
Rated (Minimum~Maximum)
Cooling 1
W
660 (205~1,200)
660 (205~1,200)
960 (205~1,300)
960 (205~1,300)
Heating 47 1
W
760 (255~1,200)
—
1,170 (340~1,660)
—
Power consumption
Heating 17 2
W
950
—
1,200
—
EER
1
[SEER]
3
Cooling
13.6 [ 21.0 ]
13.6 [ 21.0 ]
12.5 [ 20.5 ]
12.5 [ 20.5 ]
HSPF IV
4 Heating
10.0
—
10.0
—
COP Heating
1 4.20
—
3.61
—
Power supply
V , phase , Hz
208/230 , 1 , 60
Max. fuse size (time delay)
A
15
Min. circuit ampacity
A
12
12
12
12
Fan motor
F.L.A
0.50
Compressor
Model KNB073FQDHC
KNB092FQAHC
R.L.A 6.6
4.9
6.6
4.9
L.R.A 8.2
6.1
8.2
6.1
Refrigeration oil cc. (Model)
320 (NEO22)
Refrigerant control
Linear expansion valve
Sound level
1
Cooling dB(A)
46
46
49
49
Heating dB(A)
50
—
51
—
Defrost method
Reverse cycle
Dimensions
W
in.
31-1/2
D
in.
11-1/4
H
in.
21-5/8
Weight Ib.
66
77
External fi nish
Munsell 3Y 7.8/1.1
Remote controller
Wireless type
Control voltage (by built-in transformer)
VDC
12 - 24
Refrigerant piping
Not supplied
Refrigerant pipe size
(Min. wall thickness)
Liquid in.
1/4
(0.0315)
Gas in.
3/8
(0.0315)
Connection method
Indoor Flared
Outdoor Flared
Between the indoor &
outdoor units
Height difference
ft.
40
Piping length
ft.
65
Refrigerant charge (R410A)
1 lb. 12 oz.
2 lb. 9 oz.
NOTE
: Test conditions are based on ARI 210/240.
1: Rating conditions (Cooling) — Indoor: 80˚FDB, 67˚FWB, Outdoor: 95˚FDB, (75˚FWB) Rated
frequency
(Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 47˚FDB, 43˚FWB
Rated frequency
2:
(Heating)
—
Indoor: 70˚FDB, 60˚FWB, Outdoor: 17˚FDB, 15˚FWB Maximum
frequency
3
SPECIFICATION