J Check of power supply

Is there voltage 208/230 VAC

between the indoor terminal

block S1 and S2?

No

Yes

Replace the indoor

electronic control P.C.

board.

Rectify indoor/outdoor

connecting wire.

Yes

If light up, OK.

If fl ash, refer to 10-3.

Does The upper lamp of

OPERATION INDICATOR lamp on

the indoor unit light up?

Dose LED on the inverter P.C.

board light up or fl ash? (Refer

to 10-6.1.)

No

Replace the inverter

P.C. board.

Is there bus-bar voltage 260-325

VDC between DB61 (+) and DB61 (

–) on the inverter P.C. board?

(Refer to 10-6.1.)

No

Check the electric parts in main circuit.

Yes

Yes

No

Disconnect the connector (CN61)

between compressor and intelligent

power module.

Turn ON power supply and press

EMERGENCY OPERATION switch.

Inverter P.C. board

(Solder side)

DB61

260-325 VDC