beautypg.com

2. performance curve cooling – MITSUBISHI ELECTRIC MUY-GE09NA User Manual

Page 14

background image

14

2) COOLING CAPACITY CORRECTIONS

Refrigerant piping length (one way: ft.)

25 (std.)

40

65

MUZ-GE09NA
MUY-GE09NA
MUZ-GE12NA
MUY-GE12NA
MUZ-GE15NA
MUY-GE15NA
MUZ-GE18NA
MUY-GE18NA

1.0

0.954

0.878

3) HEATING CAPACITY (MUZ)

Model

Indoor air

Outdoor intake air WB temperature (˚F)

IDB (˚F)

5

15

25

35

43

45

55

TC TPC TC TPC TC TPC TC TPC TC TPC TC TPC TC TPC

MUZ-GE09NA

75

4.8

0.45

6.3

0.57

7.9

0.67

9.4

0.74

10.6

0.78

11.0

0.79

12.4

0.82

70

5.2

0.43

6.7

0.55

8.2

0.65

9.6

0.72

10.9

0.76

11.2

0.78

12.7

0.81

65

5.5

0.41

6.9

0.52

8.6

0.63

10.0

0.70

11.2

0.74

11.6

0.75

13.0

0.79

MUZ-GE12NA

75

6.3

0.69

8.4

0.87

10.4

1.02

12.5

1.14

14.0

1.20

14.5

1.22

16.4

1.26

70

6.8

0.66

8.9

0.84

10.8

1.00

12.7

1.11

14.4

1.17

14.8

1.19

16.8

1.24

65

7.2

0.63

9.1

0.81

11.3

0.97

13.2

1.08

14.8

1.14

15.3

1.16

17.1

1.22

MUZ-GE15NA

75

7.9

0.63

10.4

0.79

13.1

0.93

1.56

1.03

17.6

1.09

18.1

1.10

20.5

1.14

70

8.6

0.60

11.1

0.76

13.5

0.91

15.9

1.01

18.0

1.06

18.5

1.08

21.0

1.12

65

9.0

0.57

11.3

0.73

14.1

0.87

16.5

0.98

18.5

1.03

19.1

1.05

21.4

1.10

MUZ-GE18NA

75

9.1

0.64

11.9

0.81

14.9

0.95

17.8

1.06

20.1

1.12

20.7

1.13

23.5

1.18

70

9.8

0.62

12.7

0.78

15.5

0.93

18.2

1.04

20.6

1.09

21.2

1.11

24.0

1.16

65

10.3

0.59

13.0

0.75

16.2

0.90

18.8

1.01

21.2

1.06

21.8

1.08

24.5

1.13

NOTE

: 1. IDB: Intake air dry-bulb temperature

TC: Total Capacity (x10

3

Btu/h)

TPC: Total Power Consumption (kW)

2. Above data is for heating operation without any frost.

How to operate with fixed operational frequency of the compressor.

1. Press the EMERGENCY OPERATION switch on the front of the indoor unit, and select either EMERGENCY COOL

mode or EMERGENCY HEAT mode before starting to operate the air conditioner.

2. The compressor starts with operational frequency.

3. The fan speed of the indoor unit is High.

4. This operation continues for 30 minutes.

5. In order to release this operation, press the EMERGENCY OPERATION switch twice or once, or press any button on

the remote controller.

7-2. PERFORMANCE CURVE
Cooling

71
67
63

71
67
63

13

12

11

10

7

9

8

0.7

0.6

0.5

Indoor intake air WB temperature (°F)

Indoor

intake air WB tempe

rature (°F)

SHF at rating condition = 0.76

= 307 CFM

Airflow

65

75

85

95

105

115

Outdoor intake air DB temperature (°F)

T

o

tal power consumption

(kW)

T

o

tal capacity

(1

0

3

Btu/h)

71

63

67

71

63

67

14

15

12

10

13

11

9

1.2

1.1

1.0

0.9

0.8

0.7

Indoor intak

e air WB temperature (°F)

Indoor

intake air

WB tempe

rature (°F

)

SHF at rating condition = 0.73

= 350 CFM

Airflow

65

75

85

95

105

115

Outdoor intake air DB temperature (°F)

T

o

tal power consumption

(kW)

T

o

tal capacity

(1

0

3

Btu/h)

MUZ-GE09NA
MUY-GE09NA

MUZ-GE12NA
MUY-GE12NA

MUZ-GE15NA
MUY-GE15NA

71

67
63

71

67

63

17

18

16

15

14

11

13

12

1.3

1.2

1.1

1.0

0.9

0.8

Indoor

intake air WB te

mperat

ure (°F)

Indoor intak

e air WB tempe

rature

(°F)

SHF at rating condition = 0.80

= 498 CFM

Airflow

65

75

85

95

105

115

Outdoor intake air DB temperature (°F)

T

o

tal power consumption

(kW)

T

o

tal capacity

(1

0

3

Btu/h)

This manual is related to the following products: