Muz-ge18na muy-ge18na – MITSUBISHI ELECTRIC MUY-GE09NA User Manual

Page 12

background image

12

MUZ-GE18NA MUY-GE18NA

Outdoor

heat

exchanger

Flared connection

Defrost

thermistor

RT61

(

MUZ)

Discharge

temperature

thermistor

RT62

Flared connection

Stop valve
(with strainar)

Stop valve
(with service port)

Capillary tube

O.D. 0.142 × I.D. 0.094

Ч 1-31/32

3.6Чш2.4Ч50)

Refrigerant flow in cooling

Compressor

4-way valve

Refrigerant flow in heating

(

MUZ)

Refrigerant pipe ø1/2
(with heat insulator)

Refrigerant pipe ø1/4
(with heat insulator)

LEV

R.V. coil

(

MUZ)

heating ON
cooling OFF

Muffler

#100

Receiver

Outdoor heat

exchanger

temperature

thermistor

RT68

Ambient

temperature

thermistor

RT65

Strainer

#100

Service port

Service port

Unit: inch

Max. Length
A

Max. Height

difference

B

Indoor
unit

Outdoor unit

MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE

Model

Refrigerant piping: ft.

Piping size O.D: in.

Max. Length

A

Max. Height difference

B

Gas

Liquid

MUZ-GE09/12/15NA
MUY-GE09/12/15NA

65 40

3/8 (GE09/12)

1/2 (GE15)

1/4

MUZ-GE18NA
MUY-GE18NA

100 50

1/2