beautypg.com

MITSUBISHI ELECTRIC MUY-GE09NA User Manual

Page 38

background image

38

-4

14

32

50

68

86

104

0

10

20

30

40

50

60

70

80

90

100

Temperature(°F)

Defrost thermistor(RT61) (MUZ)

Ambient temperature thermistor(RT65)

Outdoor heat exchanger temperature thermistor(RT68)

Temperature(°F)

Discharge temperature thermistor(RT62)

32

50

68

86 104 122 140 158 176 194 212 230 248

0

100

200

300

400

500

600

700

32 50 68 86 104 122 140 158 176

0

20

40

60

80

100

120

140

160

180

200

Temperature(°F)

Fin temperature thermistor(RT64)

Resistance(k

Ω

)

Resistance(k

Ω

)

Resistance(k

Ω

)

1. Inverter P.C. board

MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUY-GE09NA MUY-GE12NA MUY-GE15NA

10-6. TEST POINT DIAGRAM AND VOLTAGE

Back side of unit

Fin temperature thermistor/R

T64

(CN642)

Ambient temperature thermistor/R

T65

(CN643)

Discharge temperature thermistor/R

T62

(CN641)

Defrost thermistor /R

T61(CN641)

(MUZ)

LEV
connector
(CN724)

Bus-bar voltage
DB61
DC 260-325 V

Front side of unit

AC 208/230 V

Smoothing
capacitor
(C62)

Output to
drive
compressor
(LDU,
LDV,
LDW)

(+)

(-)

Fuse (F701)
T3.15 AL 250 V

Smoothing
capacitor
(C61)

Smoothing
capacitor
(C63)

Fuse (F901)
T3.15 AL 250 V

R.V.coil
(CN721)
208/230
VAC

(MUZ)

Jumper wire for
changing defrost
setting (JS)(MUZ)

Output to drive outdoor fan motor (CN932)

AC 208/

230 V

Outdoor heat exchanger temperature thermistor /R

T68 (CN644)

Jumper wire
for pre-heat
control setting
(JK)

Fuse (F801)
250 V 3.15 A

LED

This manual is related to the following products: