MITSUBISHI ELECTRIC MUY-GE09NA User Manual
Page 38
38
-4
14
32
50
68
86
104
0
10
20
30
40
50
60
70
80
90
100
Temperature(°F)
Defrost thermistor(RT61) (MUZ)
Ambient temperature thermistor(RT65)
Outdoor heat exchanger temperature thermistor(RT68)
Temperature(°F)
Discharge temperature thermistor(RT62)
32
50
68
86 104 122 140 158 176 194 212 230 248
0
100
200
300
400
500
600
700
32 50 68 86 104 122 140 158 176
0
20
40
60
80
100
120
140
160
180
200
Temperature(°F)
Fin temperature thermistor(RT64)
Resistance(k
Ω
)
Resistance(k
Ω
)
Resistance(k
Ω
)
1. Inverter P.C. board
MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUY-GE09NA MUY-GE12NA MUY-GE15NA
10-6. TEST POINT DIAGRAM AND VOLTAGE
Back side of unit
Fin temperature thermistor/R
T64
(CN642)
Ambient temperature thermistor/R
T65
(CN643)
Discharge temperature thermistor/R
T62
(CN641)
Defrost thermistor /R
T61(CN641)
(MUZ)
LEV
connector
(CN724)
Bus-bar voltage
DB61
DC 260-325 V
Front side of unit
AC 208/230 V
Smoothing
capacitor
(C62)
Output to
drive
compressor
(LDU,
LDV,
LDW)
(+)
(-)
Fuse (F701)
T3.15 AL 250 V
Smoothing
capacitor
(C61)
Smoothing
capacitor
(C63)
Fuse (F901)
T3.15 AL 250 V
R.V.coil
(CN721)
208/230
VAC
(MUZ)
Jumper wire for
changing defrost
setting (JS)(MUZ)
Output to drive outdoor fan motor (CN932)
AC 208/
230 V
Outdoor heat exchanger temperature thermistor /R
T68 (CN644)
Jumper wire
for pre-heat
control setting
(JK)
Fuse (F801)
250 V 3.15 A
LED