Multiple board installation 49
Installing multiple 
PC/104-Plus modules
You can stack a maximum of four PC/104-Plus modules, shown 
in the diagram below. Note that if you have PC/104 modules in 
your computer, they must be placed at the top of the stack.
In addition, you must set the rotary switch of each PC/104-Plus 
module to a unique setting in the stack. Setting the rotary 
switch dedicates a group of PCI signals to the module in the 
stack: clock, request grant, ID select, and interrupt signals. It 
is recommended that the first module installed (the module 
closest to the Host CPU board) be configured to 0, the second 
1, and so on. The table below shows the recommended switch 
setting for each module, as well as the dedicated signals.
PCI connector
Host board
ISA connectors
Top screw
Switch
position
Module
position
Interrupt Request
grant
ID
select
0 or 4
1
Interrupt A
0
0
1 or 5
2
Interrupt B
1
1
2 or 6
3
Interrupt C
2
2
3 or 7
4
Interrupt D
2