Specifications, Electrical, Environmental – Matrox Electronic Systems II User Manual
Page 100: Electrical environmental

100 Appendix C: Technical information Matrox Meteor-II /Multi-Channel
Specifications
Electrical
Environmental
■
Min./max. ambient operating temperature: 0°C - 55° C.
■
Min./max. storage temperature: -40° C - 75° C.
■
Max. altitude for operation: 3000 meters.
■
Max. altitude for transport: 12000 meters.
■
Operating humidity: 20 - 80% relative humidity
(non-condensing)
Form Factor Operating Voltage and current
Power
Consumption
a
5 V ±5% -5 V ±5% 3.3 V ±5% 12 V ±10% -12 V ±10%
PCI
1.0 A
n/a
n/a
150 mA
75 mA
7.7 W
PC/104-Plus
140 mA 60 mA
1.03 A
15 mA
n/a
5.08 W
a. This number represents the total power consumption of the Matrox Meteor-II board only.
It does not include the power consumption of an Matrox Meteor-II MJPEG module, or of
a camera which draws current through the auxiliary power supply input.