Phone Communication Testing

26

Pager Communication

¾

To test pager communication:

1. Call the central station and tell the operator you will be testing the system. If there are voice

event notification or pager numbers programmed notify them also.

2. Verify the pager is on.
3. Test each of the panic buttons to verify they are signaling the pager correctly. (See Table 9.)

Voice Event Notification

Testing this feature requires two people; one at the installation site and the other at the location

the panel is programmed to call (Option 4 and/or 5). The phone test will fail if the phone is not

answered.

Note

Option 11 and /or 12 must be set to 10.

1. Contact the central monitoring station to inform them you are testing the system and not to

dispatch help.

2. At the system site, activate a portable panic or press the system Call button.

Note

After the panel has

announced the alarms it

says “Press star for alarm”

again. To hear the alarms

again press *. To end the call

go to step 5.

3. At the calling location, pick up the phone after it starts ringing. You should hear the panel

voice announce “Press star for alarm.”

4. Press the * button on the phone and the panel voice announces “Time is x:xx, sensor xx panic

alarm.” If the * button is not pressed and the call is ended the panel will call back 8 times.

Note

Pressing 5 on the phone at this point will start a 2-way session with the panel. See Table 10 for the

remote phone commands.

Note

You must terminate the call

by pressing #. Otherwise the

panel may not disconnect

from the phone line for up to

2 minutes.

5. After listening to the alarm information and/or having a 2-way conversation, press # to termi-

nate the call.

6. At the system site, press the Status button to clear the status message. The panel will

announce the time and the type of alarm.

If you press the Status button before the panel has delivered the Voice Event Notification the sys-

tem clears the alarm message and only the time will be announced.

Remote Phone Operation

Test the system from a remote (off-site) phone using the commands in Table 10. See “Option 20:

Ring/Hang/Ring” in the Programming section for information on connecting to CareGard from a

remote phone. After a successful Ring/Hang/Ring, enter the Master Access Code + a Phone

Command from Table 10.

Table 9: Pager Reporting Message

Report

Pager Display

Phone Test

-101-101

AC Power Restoral

-102-102

AC Power Failure

-103-103

Medication Reminder Failure

-104-104

Activity Timer Failure

-105-105

Call Button, Wrist or Pendant

Panic

-107-107

Smoke Alarm

-109-109