Adding/Replacing Sensors

22

To Add or Replace a Sensor using the Programming Buttons under

the Panel Cover

Note

The sensor number can be

changed during program

mode by pressing the num-

bered keys after pressing

the sensor button. Sensors

can be numbered 01 to 24.

Be sure to enter 0 before the

number for sensor numbers

1 to 9. The sensor number

cannot be changed after it

has been programmed.

1. Open the front cover.
2. Enter the Utility 1 or Utility 2 Access Code.
3. Press the Add button from the Start menu. The panel announces “Select from Main Menu.”
4. Press Sensor from the Main Menu.

The panel will announce “Press button on sensor X.” X is the next available sensor number. If

24 sensors are already programmed into the panel the panel says “Invalid. Twenty-four sen-

sors already programmed.”

5. Trip the sensor.

See Table 8 for descriptions of how to trip each type of sensor. The panel will announce

“Press status to accept sensor.” DO NOT press Status at this time. Move on to Step 6.

6. If necessary, change the Sensor name by pressing the Option # button.

See Table 8 for Sensor Type Options.

7. Press the Done button to program the sensor.

The system will announce the sensor name, type and number.

Table 8: Programming Sensors

Sensor Type

To Trip

Sensor Type Options

Personal Help Button

Press the help button on the sensor.

Emergency Sensor Type Not Supervised

Emergency Sensor type Supervised

Pendant Help Button

Press the help button on the sensor.

Emergency Sensor Type Not Supervised

Emergency Sensor type Supervised

Door/Window Sensor

With the Door/Window Sensor cover

removed, press the Program button on

the top of the sensor.

Activity Sensor type Supervised

Activity Sensor type Not Supervised

Freeze Sensor

With the Freeze Sensor cover

removed, press the Program button on

the top of the sensor.

Freeze Sensor type Supervised

Water Sensor

With the Water Sensor cover

removed, press the Program button on

the top of the sensor.

Water Sensor type Supervised

Smoke Alarm

Remove the base of the Smoke Alarm

Smoke Sensor type Supervised

Carbon Monoxide (CO)

Alarm

Plug in the CO Alarm. Within 60 sec-

onds of plugging in, press and hold the

Test/Reset button until you hear 6

beeps.

Carbon Monoxide Sensor type Supervised

Motion Sensor

Remove the sensor from its mounting

plate.

Activity Sensor type Supervised

Activity Sensor type Not Supervised

Repeater

With the Repeater cover removed,

press the tamper switch spring on the

circuit board.

Repeater module type Supervised