Option 30: demo mode, Range = on/off (default = off), Press add or delete – GE 60-883-95R User Manual
Page 21: Press option, Press 3, then 0, Press done, Option 31: programming report, Press 3, then 1, Option 32: supervisory time, Range = any time (default = 12:00 a.m.)
Programming Options
16
Option 30: Demo Mode
Range = On/Off (Default = Off)
Determines whether the panel operates as a demonstration model (on) or a
standard panel (off).
Turning on this feature disables low battery supervision.
When a panic is pressed the panel will announce “Contacting emergency
number. Please remain calm.” There will be a 10 second pause then the
panel will say “This is the response center, we have received your alarm. Do
you have an emergency?”
¾
To Add or Delete Demo Mode:
1. Press Add or Delete.
2. Press Option #.
3. Press 3, then 0.
4. Press Done.
Option 31: Programming Report
Range = On/Off (Default = Off)
Determines whether the panel sends a report to the central station anytime
programming mode is entered/exited (on) or not at all (off).
When Programming Report is on the panel sends a report whenever the
dealer (Utility 1) or installer (Utility 2) code is used to enter programming
mode and again when the programming session ends. The report is also sent
when the Menu button on the back of the panel is used to enter add a sensor
mode, and again when the sensor is added.
¾
To Add or Delete Programming Report:
1. Press Add or Delete.
2. Press Option #.
3. Press 3, then 1.
4. Press Done.
Option 32: Supervisory Time
Range = any time (Default = 12:00
A
.
M
.)
Determines the time of day the panel reports supervisory conditions - sensor
failures, system low battery, sensor low battery and automatic phone tests to
the central station. If Option 40 is On Medication Reminders will be
reported also.
Note
The panel clock must be set to the correct time for this option and Option 14: Auto
Phone Test to work correctly.
¾
To program Supervisory Time:
1. Press Add.
2. Press Option #.
3. Press 3, then 2.
4. Enter the desired Supervisory Time using
the Hours and Minutes buttons.
5. Press Done.
Option 33: Modem Sensitivity
Range = On/Off (Default = Off)
Determines whether the modem sensitivity is set to normal (off) or high
(on).
Note
This feature should be used only if the panel experiences consistent trouble
reporting to the central station. Otherwise, leave this option off.
¾
To Add or Delete Modem Sensitivity:
1. Press Add or Delete.
2. Press Option #.
3. Press 3, then 3 again.
4. Press Done.
Option 34: VOX Mic Gain
Range = 01-64 (Default = 14)
Sets the mic gain (sensitivity) when using voice-activated switching
(Speaker Phone).
Room size, acoustics and furnishings where the panel is located will influ-
ence the setting. The available settings are 01 (low) to 64 (high). Entries
must be 2 digits.
¾
To program VOX Mic Gain:
1. Press Add.
2. Press Option #.
3. Press 3, then 4.
4. Enter the desired VOX Mic Gain using the
numbered buttons.
5. Press Done.
Option 35: VOX Gain Range
Range = 01-64 (Default = 20)
Sets the gain range for the voice-activated switching (VOX). The available
setting are 01 (low) to 64 (high). Entries must be 2 digits. For correct perfor-
mance this option should be set equal to or greater than Option 34: VOX
Mic Gain.
Note
This option works in conjunction with Option 34: VOX Mic Gain. It is important to
follow the setting recommendations as described to achieve acceptable opera-
tion.
¾
To program VOX Gain Range:
1. Press Add.
2. Press Option #.
3. Press 3, then 5.
4. Enter the desired VOX Gain Range using
the numbered buttons.
5. Press Done.