beautypg.com

Option 27: rf jam detect, Range = on/off (default = off), Press add or delete – GE 60-883-95R User Manual

Page 20: Press option, Press 2, then 7, Press done, Option 28: access code length, Range = 3-6 (default = 4), Press add, Press 2, then 8

background image

Programming Options

15

Option 27: RF Jam Detect

Range = On/Off (Default = Off)

Determines whether the panel checks for and reports RF interference/jam to

the central station (on), or not (off).
If this option is on and the panel receives a constant 319.5 MHz signal, the

panel announces “RF interference detected” when the Status button is

pressed and reports the condition to the central station. If this option is off,

the panel does not detect an RF jam.

Note

The panel will not detect RF Jams for 4 hours after the initial power up or a mem-

ory clear.

RF Jam Detect must be turned on for ETL (UL 1635) listed systems.

¾

To Add or Delete RF Jam Detect:

1. Press Add or Delete.
2. Press Option #.
3. Press 2, then 7.
4. Press Done.

Option 28: Access Code Length

Range = 3-6 (Default = 4)

Determines how many digits are in each access code.
This option lets you set the access code length to 3, 4, 5 or 6 digits. Turning

off (deleting) this option resets access code length and all access codes to

their default.
Read the following before changing this option.
• This option affects all access codes.
• Changing the access code length resets the Master, Utility 1 and Utility 2

access codes to their respective defaults as described in Table 6.

Note

If the customer wants the Access Code Length changed, it should be set before

programming any new (unprogrammed) access codes, whenever possible.

¾

To program Access Code Length:

1. Press Add.
2. Press Option #.
3. Press 2, then 8.
4. Enter the desired Access Code Length using

the numbered buttons.

5. Press Done.

Table 6: Access Code Length Defaults

Setting

Default Code

3

Master - 123

Utility 1 - 321

Utility 2 - 321

4

Master - 1234

Utility 1 - 4321

Utility 2 - 4321

5

Master - 12345

Utility 1 - 54321

Utility 2 - 54321

6

Master - 123456

Utility 1 - 654321

Utility 2 - 654321

Option 29: RF Phone Answer

Range = On/Off (Default = On)

When this option is on pressing a panic button or the panel call button will

answer a ringing phone. Pressing it again will hang-up the phone.

Important !

The phone must be hung up by pressing the panic button. If the phone is not hung

up the phone line may be held (unavailable) for up to 30 minutes.

Note

If a different panic than the one used to answer the phone is used to hang-up the

phone, the panel will disconnect and go into alarm.

¾

To Add or Delete RF Phone Answer:

1. Press Add or Delete.
2. Press Option #.
3. Press 2, then 9.
4. Press Done.