Replacing the backup battery, Figure 5. replacing the backup battery, Remove the old battery – GE 60-883-95R User Manual
Page 29: Tighten the speaker screws, Replace the battery cover, Replace and tighten the cover screw, Replace the panel cover, Sensor low battery, The status light turns on, Sensor supervisory failure
System Monitoring
24
Replacing the Backup Battery
¾
To replace the backup battery:
1. Turn the ON/OFF switch on the back of the panel to OFF.
2. Remove the panel cover by lifting on the tab at the top of the panel.
3. Loosen the speak screws. This makes removing the battery easier.
4. Remove the battery cover screw and cover. (See Figure 3)
Figure 5. Replacing the backup battery
Note
Lifting the panel and tilting it
toward yourself should aid in
the removal of the battery.
5. Remove the old battery.
6. Disconnect the cables from the old battery and connect them to the new one.
7. Install the new battery, positioning it under the edge of the speaker.
8. Carefully place the connecting wires above the speaker.
9. Tighten the speaker screws.
10. Replace the battery cover.
11. Replace and tighten the cover screw.
12. Replace the panel cover.
Sensor Low Battery
¾
If the panel gets a low battery message from a sensor, the following occurs:
Note
If Status is pressed during a
sensor low battery, the sys-
tem announces “Time is
x:xx, sensor X panic, low
battery” and the panel will
stop beeping for 4 hours.
1. The panel sends a Sensor Low Battery report to the central station.
2. The Status light turns on.
3. If Option 25: Trouble Beeps is enabled, six trouble beeps will sound once a minute.
When the low battery condition is fixed, the panel stops the trouble beeps and turns off the Status
light. See the sensor manual for information on replacing its battery.
Sensor Supervisory Failure
¾
If the panel does not hear from a sensor within the programmed RF Timeout (Option 15)
the following occurs:
1. The panel sends a Sensor Supervisory Failure report to the central station.
2. The Status light turns on.
3. If Option 25: Trouble Beeps is enabled, six trouble beeps will sound once a minute.
+
-
+
-
START MENU
MAIN MENU
Delete
press
Delete
To delete an option or access code
and follow voice prompts.
Cancel
Cancel
Minutes
See Note
DONE
, then
If you make a mistake or want to start
over press
Account No.
Add Option
I N S T R U C T I O N S
Add
Add
Press
Clock Set
DONE
Option #
Press
Set Clock
Phone No.
Option #3:
Option #2:
Panel Voice Enable
Option #1:
Press for program information.
*
use red numbers to enter access code.
voice prompts.
Add Access Code
Hours
Access Code
See Note
Hold key or press repeatedly
until you hear the desired item.
Note:
See Note
Press
and follow
Add
Cancel
Access Code
Sensor
Option #
*
*
Delete
Test
Clock Set
DONE
Hours
Minutes
422-30
1
3
R
ev
A
2
4
5
3
1
8
9
0
7
6
+
-
+
-
START MENU
MAIN MENU
Delete
press
Delete
To delete an option or access code
and follow voice prompts.
Cancel
Cancel
Minutes
See Note
DONE
, then
If you make a mistake or want to start
over press
Account No.
Add Option
I N S T R U C T I O N S
Add
Add
Press
Clock Set
DONE
Option #
Press
Set Clock
Phone No.
Option #3:
Option #2:
Panel Voice Enable
Option #1:
Press for program information.
*
use red numbers to enter access code.
voice prompts.
Add Access Code
Hours
Access Code
See Note
Hold key or press repeatedly
until you hear the desired item.
Note:
See Note
Press
and follow
Add
Cancel
Access Code
Sensor
Option #
*
*
Delete
Test
Clock Set
DONE
Hours
Minutes
422-30
1
3
R
ev
A
2
4
5
3
1
8
9
0
7
6
Battery Cover
Backup Battery
Slide cover off to the
right
Cover Screw
Speaker Screws