Option 13: dtmf dialing, Range = on/off (default = on), Press add or delete – GE 60-883-95R User Manual
Page 17: Press option, Press 1, then 3, Press done, Option 14: auto phone test, Range = off, 001-254 days (default = off), Press add, Press 1, then 4
Programming Options
12
Option 13: DTMF Dialing
Range = On/Off (Default = On)
Determines whether the panel uses DTMF (on) or pulse (off) for dialing pro-
grammed phone numbers.
¾
To Add or Delete DTMF Dialing:
1. Press Add or Delete.
2. Press Option #.
3. Press 1, then 3.
4. Press Done.
Option 14: Auto Phone Test
Range = Off, 001-254 days (Default = Off)
Determines whether the panel automatically performs a periodic phone test.
The test interval can be from 001 to 254 days. Entries must be 3 digits. The
time of day the panel performs the test is determined by Option 32: Supervi-
sory Time, which must be turned on for this feature to work.
Note
Auto Phone Test must be set to 001 for ETL (UL 1635) listed systems.
¾
To program Auto Phone Test:
1. Press Add.
2. Press Option #.
3. Press 1, then 4.
4. Enter the desired Auto Phone Test days
using the numbered buttons.
5. Press Done.
Option 15: RF Timeout
Range = 02-24 hours (Default = 12 hours)
Determines the time period within which the panel must receive at least one
supervisory signal from a learned sensor before identifying a sensor failure
for that sensor and sounding trouble beeps. Any sensor failure is reported
immediately and again at the supervisory time (Option 32: Supervisory
Time). See “Sensor Supervisory Failure” in the System Operation section
for more information.
The Timeout can be set from 02 to 24 hours. Entries must be 2 digits.
Note
Setting this feature to 2 hours may cause false reports.
RF Timeout must be set to 4 hours for ETL (UL 1635) listed systems.
¾
To program Auto Phone Test:
1. Press Add.
2. Press Option #.
3. Press 1, then 4.
4. Enter the desired Auto Phone Test days
using the numbered buttons.
5. Press Done.
Option 16: Manual Phone Test
Range = On/Off (Default = On)
Determines whether the user can perform a manual phone test to verify com-
munication to a central station/pager (on), or not (off).
¾
To Add or Delete Manual Phone Test:
1. Press Add or Delete.
2. Press Option #.
3. Press 1, then 6.
4. Press Done.
Option 17: AC Power Failure Report
Range = Off, 0-254 Min (Default = 60 Min)
Determines whether the panel sends AC Power failure reports to a central
station or pager after the programmed time period expires (on), or not (off).
After 30 seconds without AC Power the panel lights turn off. When the
panel is without AC Power for the programmed time, an AC power failure is
reported. The AC Power Failure Report time period can be set from 5 to 254
minutes. Entries must be 3 digits. The panel reports an AC power restoral
when AC power returns to the panel.
Note
AC Power Failure Report must be set to 15 minutes for ETL listed systems.
¾
To program an AC Power Failure Report
Time:
1. Press Add.
2. Press Option #.
3. Press 1, then 7.
4. Enter the desired AC Power Failure Report
Time in minutes using the numbered but-
tons.
5. Press Done.