User instructions, Fitting the glass window - e-box, Flame failure device – Stovax E-Studio PR0776 User Manual
Page 9: Running in, Servicing
9
USER INSTRUCTIONS
21
AR1408
A4
A5
A3
A6
• Place the next four pebbles as shown resting between the
flame baffle and the first row of pebbles, Diagram 22.
22
AR1409
A1
A2
A1
• Place the remaining two A3 pebbles as shown in
Diagram 23.
23
AR1410
A3
A3
6.7 The coals/pebbles should evenly cover the whole bed with
the gaps between them kept equal. This will maximise the
performance of the product.
6.8 ENSURE ThAT ThE COAlS/PEBBlES ARE POSITIONED
AS ABOvE. ONlY USE ThE CORRECT AMOUNT OF
COAlS/PEBBlES AS SPECIFIED IN ThE DIAGRAMS.
FITTING ThE GlASS wINDOw - E-BOX
6.9 • Ensure that the fibre glass window seal on the box is
intact, then lower the glass window into the lower retaining
bracket.
• Hold the window and position the upper retaining
bracket
• Secure using the 4 screws.
• Tighten the bottom and top screws to retain the window,
Diagram 24.
24
AR1465
AR1423
• Refer to the separate Frame Instructions to replace the
frame on the fire.
NEvER OPERATE ThE APPlIANCE whEN ThE GlASS
PANEl IS REMOvED OR BROKEN.
7. FlAME FAIlURE DEvICE
7.1 This is a safety feature incorporated on this appliance which
automatically switches off the gas supply if the pilot goes
out and fails to heat the thermocouple.
8. RUNNING IN
8.1 The surface coating on the coals used in your GAZCO fire
will "burn off" during the first few hours of use producing a
harmless and temporary odour. This will disappear after a
short period of use. If the odour persists, ask your installer
for advice.
9. SERvICING
9.1 The fire must be serviced every 12 months by a qualified
Gas Engineer. In all correspondence always quote the
Model number and the Serial number which may be found
on the databadge.