beautypg.com

Installation instructions, Installation, Recessed installation – Stovax E-Studio PR0776 User Manual

Page 18: Installation of the appliance

background image

18

INSTAllATION INSTRUCTIONS

INSTAllATION

6.6 The void into which the appliance is fitted must be

ventilated to prevent a build up of heat. If the void is sealed

then it will be necessary to fit vents at both low and high

levels of approximately 50cm

2

. These vents should take cold

air from the room and return warm air back into the room.

This method of installation requires structural alteration to

the intended location. A suitable supporting lintel must be

installed to maintain the structural integrity of the

surrounding blockwork.

7. RECESSED INSTAllATION

7.1 Mark the position of the lintel so that it sits centrally over

the intended installation. Remove the blockwork and install

the lintel using mortar to ensure a strong bond with the

surrounding wall, Diagram 5.

5

AR0705

7.2 With the lintel in position mark the width of the aperture

and remove the blockwork. If there is loose cavity insulation

this must be retained. This can be achieved by using

Rockwool or similar, Diagram 5.

7.3 Mark the position of the flue on the wall by measuring from

the top of the finished hearth level, Diagram 6.

6

AR1436b

7.4 A 152mm (6’) diameter hole is required to install the flue.

This can be achieved by either:

a) Core drill

b) Hammer and chisel

It is advisable to drill small holes around the circumference

when using method b. Make good both ends of the hole.

8. INSTAllATION OF ThE APPlIANCE

8.1 The flue can be cut to length, measure the thickness of the

wall the flue is passing through, then deduct 12mm. This is

the length required when measuring from the line on the

flue label. This must be level with the outside wall face

when fitted, Diagram 7.

7

AR0630

8.2 There is a cardboard fitment in the terminal. This is to

support the flue whilst it is cut to length. REMOvE ThE

REMAINDER OF ThE CARDBOARD AFTER CUTTING TO

SIZE

• Remove the compression elbow from the appliance and

connect it to the gas supply pipe, taking note of its

orientation

• Attach the flue to the appliance and seal using the

aluminium tape provided

8.3 As the appliance is positioned into the opening of the

enclosure, pass the flue pipe through the hole in the wall. It

will be necessary to pass the supply pipe with the elbow

through the silicone panel on the right hand side of the box.

• Secure the appliance in place using screws and rawl

plugs provided

• PURGE THE SUPPLY PIPE. This is essential to expel any

debris that may block the gas controls. Connect the elbow

to the appliance inlet pipe.

8.4 • Connect a suitable pressure gauge to the test point

located on the inlet elbow and turn the gas on

• Light the appliance and check for leaks

• Turn the appliance to maximum and check that the

supply pressure is as stated on the databadge

• Turn the gas supply off and replace the test point screw

• Turn the gas on and check the test point for leaks