Servicing instructions, Replacing parts, Pilot unit – Stovax E-Studio PR0776 User Manual
Page 27: 2b. e-box
27
• Remove the ceramic coals and fuel bed and place on a
dry clean surface
• Remove the ceramic panels from inside the appliance
• Remove the two screws securing the front U channel on
the burner assembly. This is to gain access to the burner
retaining screws, Diagram 8.
8
AR1432
2.14 • Remove the 11 screws in the burner tray securing the
burner assembly to the appliance. The burner assembly can
now be removed by lifting it up and out of the appliance,
Diagram 9.
9
AR1433
3. PIlOT UNIT
The pilot unit assembly consists of three components which
can be individually changed, these are:-
1) Pilot Injector
2) Electrode
3) Thermocouple
Note: On the E-Box, access is provided for the removal of the
pilot without removing the engine assembly. It is easier,
however, to change the pilot by removing the whole
assembly.
5
AR2001
5
• Remove the 11 screws that fix the burner assembly into
the appliance, Diagram 6. The burner assembly can now
be removed by lifting it up and out of the appliance.
5
AR1980
6
2B. E-BOX
• Remove the glass window by loosening the four screws in
the lower retaining bracket then remove the four top screws
and retaining bracket. The glass window can now be lifted
clear, Diagram 7
AR1423
7
AR1465
SERvICING INSTRUCTIONS
REPlACING PARTS