Installation instructions, Site requirements, Flue and chimney requirements – Stovax E-Studio PR0776 User Manual
Page 14: Uk dimensions
14
INSTAllATION INSTRUCTIONS
SITE REQUIREMENTS
1. FlUE AND ChIMNEY REQUIREMENTS
NOTE: This appliance can only be installed in
conjunction with the flue supplied.
1.1 The flue must be sited in accordance with BS5440: Part 1
(latest edition), Diagram 1.
1.2 Any terminal which is less than 2 metres above any access
(level ground, balcony or above a flat roof to which people
have access) is to be fitted with a guard.
1.3 The flue must be securely fixed and fire precautions
followed in accordance with local and national codes of
practice.
1.4 The horizontal terminal can be reduced in length, Diagram
2.
2
AR0630
1
* In addition, the terminal should not be nearer than
300mm to an opening in the building fabric formed for the
purpose of accommodating a built-in element such as a
window frame.
H The reference to external corners does not apply to
building protrusions not exceeding 450mm, such as disused
chimneys on external walls.
Dimension
Terminal Position
Minimum
Distance
(mm)
A*
Directly below an opening, air brick, opening widows etc
300 mm
B*
Above an opening, air brick, opening windows etc.
300 mm
C*
Horizontal to an opening, air brick, opening windows etc.
300 mm
D
Below gutters, soil pipes or drain pipes
300 mm
E
Below eaves
300 mm
F
Below balconies or car port roof
600 mm
G
From a vertical drain pipe or soil pipe
300 mm
H
From an internal or external corner
600 mm
I
Above ground, roof or balcony level
300 mm
J
From a surface facing the terminal (or boundary)
600 mm
K
From a terminal facing the terminal
600 mm
L
From an opening in the car port (e.g. door, window) into dwelling
1200 mm
M
Vertically from a terminal on the same wall
1500 mm
N
Horizontally from a terminal on the same wall
300 mm
O
From the wall in which the terminal is mounted
N/A
P
From a vertical structure on the roof
N/A
Q
Above intersection with roof
N/A
UK Dimensions