User instructions, Cleaning the fire, 5a. cleaning the e-studio – Stovax E-Studio PR0776 User Manual
Page 5: 5b. cleaning the e-box
5
USER INSTRUCTIONS
TIMER MODE it will turn the fire on and off according to
pre-set programme and automatically regulate the room
temperature during the two periods. GAZCO PART NO.
8456.
ClEANING ThE FIRE
ENSURE ThE FIRE IS COlD BEFORE PROCEEDING
5.1 • Refer to the separate Frame Instructions to remove the
frame from the fire.
5A. ClEANING ThE E-STUDIO
5.2 • Remove the glass window by unscrewing the 8 screws in
the glass window frame, Diagram 2
2
AR1996
5.3 To clean the glass surface, Gazco recommends you use a
ceramic glass product generally sold for cleaning ceramic
hobs.
• Remove the granite chippings and place on a dry clean
surface. Do not remove the enamel back panel
• Use a damp cloth and mild non-abrasive cleaner on the
enamel back panel
• Clean the burner and tray assembly using a vacuum
cleaner with a soft brush attachment
• Ensure all debris is removed from the burner ports
• Replace the granite chippings by referring to Section 6A
for E-Studio.
5B. ClEANING ThE E-BOX
5.4 • Remove the glass window by loosening the four screws in
the lower retaining bracket
• Remove the four top screws and retaining bracket. The
glass window can now be lifted clear. See diagram 3.
3
AR1465
AR1423
5.5 To clean the glass surface, Gazco recommends you use a
ceramic glass product generally sold for cleaning ceramic
hobs.
• Remove the ceramic coals or pebbles and fuel bed and
place on a dry clean surface
• Clean the burner and tray assembly using a vacuum
cleaner with a soft brush attachment
• Ensure all debris is removed from the ports
• Replace the ceramics by referring to section 6B
ADvICE ON hANDlING AND DISPOSAl OF FIRE
CERAMICS
The fuel effect and side panels in this appliance are made
from Refractory Ceramic Fibre (RCF), a material which is
commonly used for this application.
Protective clothing is not required when handling these
articles, but we recommend you follow normal hygiene
rules of not smoking, eating or drinking in the work area
and always wash your hands before eating or drinking.
To ensure that the release of RCF fibres are kept to a
minimum, during installation and servicing a HEPA filtered
vacuum is recommended to remove any dust accumulated
in and around the appliance before and after working on it.
When servicing the appliance it is recommended that the
replaced items are not broken up, but are sealed within
heavy duty polythene bags and labelled as RCF waste.
RCF waste is classed as stable, non-reactive hazardous waste
and may be disposed of at a licensed landfill site.
Excessive exposure to these materials may cause temporary
irritation to eyes, skin and respiratory tract; wash hands
thoroughly after handling the material.