Test run – Grizzly G0651 User Manual
Page 33

model g0651/g0652 (mfg. since 1/10)
-31-
Test Run
test run your machine to make sure it runs prop-
erly and is ready for regular operation.
the test run consists of verifying the following:
1) the motor powers up and runs correctly, 2)
the safety disabling mechanism on the switch
works correctly, and 3) the blade turns the correct
direction (the machine is not wired out of phase—
g0652 only).
if, during the test run, you cannot easily locate
the source of an unusual noise or vibration, stop
using the machine immediately, then review the
Troubleshooting on page 67.
if you still cannot remedy a problem, contact our
tech support at (570) 546-9663 for assistance.
To test run the machine:
1. make sure you have read the safety instruc-
tions at the beginning of the manual and that
the machine is set up properly.
2. make sure all tools and objects used during
setup are cleared away from the machine.
3. lower the blade all the way down.
4. Check to make sure the machine is connect-
ed to the power source. if it is not connected,
do so now. refer to
power connection on
page 30 for instructions.
5. remove the switch disabling lock.
6. verify that the machine is operating correctly
by pressing the on button.
—When operating correctly, the machine
runs smoothly with little or no vibration or
rubbing noises.
— investigate and correct strange or unusual
noises or vibrations before operating the
machine further. always disconnect the
machine from power when investigating or
correcting potential problems.
7. turn the machine OFF.
8. insert the switch disabling lock through the
green on button, as shown in
Figure 35.
9. press the green on button to test the dis-
abling feature on the switch.
—if the machine does not start, the switch
disabling feature is working as designed.
Continue to the next step.
—if the machine starts, immediately stop the
machine. the switch disabling feature is
not working correctly. this safety feature
must work properly before proceeding with
regular operations. Call tech support for
help.
10. Model G0652 Only: verify that the power
is not connected out of phase by starting/
stopping the table saw and determining if the
motor turns in the correct direction using the
criteria below:
— if the blade turns clockwise (standing at the
left front side of the table saw), it is turning
in the correct direction. go to
Step 11.
— if the blade turns counterclockwise and
toward the back of the saw (standing at the
left front side of the table saw), it is turning
in the wrong direction.
stop the table saw, disconnect the power
source, and refer to
correcting phase
polarity on page 18 for detailed instruc-
tions on reversing the phase polarity.
11. the saw is now ready to operate.
Figure 35. switch disabling lock inserted into on
button.
lock
on Button