beautypg.com

2 discontinued support – FUJITSU BS2000 User Manual

Page 36

background image

35

SX150:

- SXFCTX24-112-L2H: FibreCAT TX24 (LTO2) via SCSI-LVD on
controller SX70F-CS12

- SXFCTX24-112-L3F: FibreCAT TX24 (LTO3) via fibre channel
- SX9084-221F-L2 (LTO2) via fibre channel


Notes:

*2

A CS12 controller is to be assigned exclusively to a TX24 de-

*2

vice with SCSI connection (no parallel use of the second slot

*2

in the CS12 controller).
Software support is via the device management. It is not

necessary to use MAREN/ROBAR.
Only cartridges from FSC with barcode label (FSC Preferred

Quality) are recommended.
Before outputting a sled, the device must be switched to AUTO-

MATIC-MODE or LCD (MANUAL) mode if it is in RANDOM-MODE.
For LTO-3 drives the X2000 V3.0A09 correction version is re-

quired. It was released in 2007, January.

MTC archive systems (SX130, SX140, SX150):

- AML systems (AML/E, AML/J, AML/2) via 3971 channel adapter

(channel type S) with drives 3591-B -BU -E, via fibre channel

with drives 3591-EFx

- SCALAR 1000 with drives

3591-EFx (fibre channel) and 3591-B -BU -E (channel adapter)
LTO1 with PSFR-CP42ML or FCROUT-SNC5100 (FC) router

LTO2 with FCROUT-SNC5100 (FC) router

- SCALAR I2000 with LTO2-, LTO3-drives (only on SX140, SX150

server families)

- SCALAR 10000 with LTO2-, LTO3-drives (only on SX140, SX150

server families)

- SCALAR i500 with LTO3-drives (only on SX140, SX150 server

families)

Notes:
Only the AML robot archives AML/x and Scalar 1000 from ADIC

Germany are supported.
For LTO-drives only cartridges from FSC with barcode label

(FSC Preferred Quality) are recommended.
For LTO-3 drives the X2000 V3.0A09 correction version is

required. It was released in 2007, January.


CentricStor


- Virtual Tape Appliance VTA-xxxx (formerly 3595-100, -400)

via Type S channel (not SX100) and fibre channel
- Virtual Tape Controller VTC (formerly ITC-R1)

via Type S channel (not SX100) and fibre channel
- Smart Backup Unit SBU-BS2 system with Scalar 100 Library or

Scalar i500 via Type S channel (not SX100) and fibre channel

A CentricStor can also be connected directly (without switch)
via the FC connection on SX series business servers.


Note:

On SX servers with fibre channel connection to CentricStor,
CentricStor compresses the data regardless of the device type

in BS2000 (also for T-C3), if the compression mode HOST is set
in menu “Logical Drives” of CentricStor configuration menu.


4.5.2

Discontinued support