Appendix c.5.3 – FieldServer FS-8700-80 User Manual

Page 38

background image

McQuay Micro Tech Open Protocol Driver Manual

Page 38 of 43

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com

Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]

Array Location Read/Write/Both Field Name

Number of Bytes Base Address Device Scaling Method

18

r

Circuit #1 Liquid Line Temperature

2

0x0479

6

19

r

Circuit #1 Previous Alarm

1

0x0833

1

20

r

Circuit #1 Status

1

0x0428

1

22

r

Circuit #1 Subcooling Temperature

2

0x049B

2

24

r

Circuit #1 Suction Temperature

2

0x0475

6

26

r

Circuit #1 Superheat Temperature

2

0x0493

2

28

r

Circuit #2 Condenser Approach Temperature

2

0x0499

2

30

r

Circuit #2 Condenser Pressure

2

0x0469

2

32

r

Circuit #2 Alarm Conditions: Condenser Pressure 2

0x082A

2

34

r

Circuit #2 Alarm Conditions: Evaporator Pressure 2

0x0828

2

36

r

Circuit #2 Alarm Conditions: Liquid Line Tempe

2

0x082E

6

38

r

Circuit #2 Alarm Conditions: Suction Temperature 2

0x082C

6

39

r

Circuit #2 Current Alarm

1

0x0832

1

41

r

Circuit #2 Evaporator Pressure

2

0x0465

2

43

r

Circuit #2 Liquid Line Temperature

2

0x047B

6

44

r

Circuit #2 Previous Alarm

1

0x0834

1

45

r

Circuit #2 Status

1

0x0429

1

47

r

Circuit #2 Subcooling Temperature

2

0x049D

2

49

r

Circuit #2 Suction Temperature

2

0x0477

6

51

r

Circuit #2 Superheat Temperature

2

0x0495

2

53

r

Compressor #1 Operating Hours

2

0x0862

1

55

r

Compressor #1 Starts

2

0x086A

1

57

r

Compressor #2 Operating Hours

2

0x0864

1

59

r

Compressor #2 Starts

2

0x086C

1

61

r

Compressor #3 Operating Hours

2

0x0866

1

63

r

Compressor #3 Starts

2

0x086E

1

65

r

Compressor #4 Operating Hours

2

0x0868

1

67

r

Compressor #4 Starts

2

0x0870

1

69

r

Condenser Entering Water Temperature

2

0x0470

6

71

r

Condenser Leaving Water Temperature

2

0x0472

6

73

r

Evaporator Entering Water Temperature

2

0x046E

6

75

r

Evaporator Leaving Water Temperature

2

0x0461

6

76

r

Heat/Cool Switch

1

0x08B4

1

78

r

OaT

2

0x047D

6

79

r

Stage of Capacity

1

0x042B

1

80

r

Unit % RLA

1

0x0474

1

81

r

Unit Status

1

0x0427

1

82

b

Clear Circuit #1 Alarm

1

0x091A

1

83

b

Clear Circuit #2 Alarm

1

0x091B

1

84

b

Condenser Leaving Water Temperature Setpoint 1

0x097D

1

85

b

Evaporator Entering Water Temperature Setpoint 1

0x090D

4

86

b

Evaporator Leaving Water Temperature Setpoint 1

0x0905

4

87

b

Maximum Water Reset Setpoint

1

0x090C

4

88

b

Network Command

1

0x044F

1

89

b

Network Demand Limit

1

0x044D

1

90

b

Network Leaving Water Temperature Reset

1

0x044E

1

91

b

Reset Option Setpoint

1

0x090B

1

Appendix C.5.3.

Equipment Type: 100CFC 100 Series Centrifugal Chiller

Array Location Read/ Write/ Both Field Name

Number of Bytes Base Address Device Scaling Method

1

r

Alarm Contact

1

0x0217

1

2

r

Approach Condenser

1

0x0418

1

3

r

Calculated Leaving Evaporator Temp Setpoint

1

0x0420

7