One-piece deep wall sleeve installation (pdxwsext), Lintel installation – Friedrich 920-087-09 (12/10) User Manual
Page 9

9
FRP010
NOTE: Construct wall opening to comply with all applicable building codes.
MAIN STUDS
JACK STUDS
LINTEL
MOUNTING
SCREW HOLES
NO HOLES IN BOTTOM OF WALL
SLEEVE UNLESS DRAIN KIT IS USED
MAIN STUDS
JACK STUDS
5. Drill.two.3/16".holes.through.each.side.of.the.sleeve.approximately.
4".from.top.and.4".from.bottom.of.sleeve...Screw.four.#10.x.1".
screws.(included).or.appropriate.fasteners.for.your.installation,.
through.the.holes.in.the.sides.of.the.wall.sleeve.
6. Apply.sealant.around.the.wall.sleeve.where.it.projects.through.the.
inside.and.outside.wall.surfaces...Apply.the.sealant.to.the.screw.
heads.or.the.tops.of.the.fasteners.used.in.Step.#5.
7. If.the.chassis.and.exterior.grille.are.to.be.installed.later,.leave.the.
weatherboard.and.center.support.in.place,.otherwise.remove.and.
dispose.of.them...(See.Figure.13,.Page.12).
8. Provide.a.support.lintel.if.the.wall.sleeve.is.installed.in.a.concrete.
or.masonry.wall.(See.Figure.10,.Page.9).
Figure 10
Lintel Installation
One-Piece Deep Wall Sleeve
Installation (PDXWSEXT)
If.the.wall.is.thicker.than.13.1/4”.a.deep.wall.sleeve.or.wall.sleeve.extension.
MUST.be.used...The.deep.wall.sleeve.may.be.special.ordered.through.
your.Sales.Representative.
- 7,200 BTU Packaged Terminal Air Conditioner Warranty 7,200 BTU Packaged Terminal Air Conditioner Installation and Operation Manual ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty A-SERIES 24,000 BTU/h 9 HEAT PUMPS 7,200 BTU Packaged Terminal Air Conditioner Product Profile ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty Guide ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Installation Guide ZoneAire Series Electric Heat Packed Terminal Air Conditioner Installation Manual ZoneAire Series 14,500 BTU Smart Packaged Terminal Air Conditioner Installation Guide 12,000 BTU FreshAire® Package Terminal Air Conditioner Installation Manual