How to connect, Warning, Junction box location – Friedrich 920-087-09 (12/10) User Manual
Page 19: Power connection, Wire clamp, Figure 25, Figure 26
19
How To Connect
IMPORTANT: Please read following electrical safety data carefully.
1. Remove.front.panel..See.Figure.22.
2. Remove.junction.box.
•
Remove.junction.box.cover.by.removing.three.screws.from.
front..Remove.junction.box.by.taking.out.top,.rear.and.side.
screws..See.Figure.25.
WARNING
Electrical Shock and/or Unit
Operation and Damage Hazard
Failure to follow this warning could result in
personal injury or death and/or unit damage.
●
●
●
●
●
●
●
Follow the National Electrical Code (NEC)
or local codes and ordinances.
For personal safety, this unit
MUST BE
properly grounded.
Protective devices (fuses or circuit breakers)
acceptable for unit installations are specified
on the nameplate of each unit.
Do not use an extension cord with this unit.
Aluminum wiring in the building may present
special problems - consult a qualified
electrician.
When unit is in STOP position, there is
still voltage to the electrical controls.
Disconnect power to unit before servicing by:
1. Removing power cord (if it has one) from
wall receptacle.
2. Removing branch circuit fuses or turning
circuit breakers off at panel.
FRP017
UNIT
CONNECTOR
JUNCTION BOX
JUNCTION BOX COVER
High
Med
Low
Fan
Cool
Heat
Fan Spee
d
Mode
Temperatur
e
Power
Figure 25
Junction Box Location
Figure 26
Power Connection
FRP018
ACCESSORY
POWER SUPPLY CORD
OR HARD WIRE
High
Med
Low
Fan
Cool
Heat
Fan Spe
ed
Mode
Temperatur
e
Power
3. Connect.accessory.power.supply.cord.or.hard.wire.connector.to.
unit.connector..See.Figure.26.
•
Units.must.be.installed.using.the.appropriate.power.supply..
kit..See.Table.2.--POWER.CONNECTION.CHART..These.
connections.must.be.followed.
See.Table.2.on.page.14.for.power.cord.accessory.options.and.ratings.
4. Reinstall.junction.box.and.cover.
•
Use.wire.clamp.to.attach.power.cord.to.basepan..Secure.
with.screws.(included).See.Figure.27.
•
Replace.junction.box.and.cover.with.screws.removed.from.
Step.2..Tighten.securely.
5. Replace.front.panel..See.Figure.24.
6. Connect.power.to.unit.
Figure 27
Wire Clamp
FRP019
WIRE CLAMP
High
Med
Low
Fan
Cool
Heat
Fan Spee
d
Mode
Temperatu
re
Power
- 7,200 BTU Packaged Terminal Air Conditioner Warranty 7,200 BTU Packaged Terminal Air Conditioner Installation and Operation Manual ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty A-SERIES 24,000 BTU/h 9 HEAT PUMPS 7,200 BTU Packaged Terminal Air Conditioner Product Profile ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty Guide ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Installation Guide ZoneAire Series Electric Heat Packed Terminal Air Conditioner Installation Manual ZoneAire Series 14,500 BTU Smart Packaged Terminal Air Conditioner Installation Guide 12,000 BTU FreshAire® Package Terminal Air Conditioner Installation Manual