Alternate wall installations, Panel wall, Curtain wall – Friedrich 920-087-09 (12/10) User Manual
Page 7: Frame and brick veneer, Block and brick veneer
![background image](/manuals/105212/7/background.png)
7
NOTE:.
Follow.all.wall.system.manufacturer.installation.instructions...For.sunrooms.and.modular.buildings,.adhere.to.their.installation.instructions.for.
supporting.and.sealing.sleeve.to.their.frames...All.wall.and.window/wall.installations.must.provide.for.proper.drainage...In.applications.where.the.
drain.holes.on.the.PTAC.wall.sleeve.are.not.exposed.beyond.the.wall.an.internal.drain.system.is.recommended...It.is.the.installer's.responsibility.
to.ensure.there.is.adequate.drainage.for.the.PTAC.unit.
Alternate Wall Installations
FRP003
OPTIONAL SUBBASE
LEVELING SCREW
Figure 4
Panel Wall
FRP004
CASE FLANGE
(BY OTHERS)
WALL OR
WINDOW
1/4" MIN
PROJECTION
OPTIONAL SUBBASE
LEVELING SCREW
Figure 6
Curtain Wall
FRP005
1/4" MIN
PROJECTION
OPTIONAL SUBBASE
LEVELING SCREW
WOOD FRAME
STEEL
LINTEL
11" MIN.
WITH SUBBASE
FRP006
1/4" MIN
PROJECTION
STEEL
LINTEL
FINISHED FLOOR
POWER SUPPLY CONDUIT
(SUPPLIED BY INSTALLER)
RECEPTACLE
CONCRETE LINTEL
13-3/4" MIN.
WITHOUT SUBBASE
Figure 5
Frame and Brick Veneer
Figure 7
Block and Brick Veneer
- 7,200 BTU Packaged Terminal Air Conditioner Warranty 7,200 BTU Packaged Terminal Air Conditioner Installation and Operation Manual ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty A-SERIES 24,000 BTU/h 9 HEAT PUMPS 7,200 BTU Packaged Terminal Air Conditioner Product Profile ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty Guide ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Installation Guide ZoneAire Series Electric Heat Packed Terminal Air Conditioner Installation Manual ZoneAire Series 14,500 BTU Smart Packaged Terminal Air Conditioner Installation Guide 12,000 BTU FreshAire® Package Terminal Air Conditioner Installation Manual