Warning – Friedrich 920-087-09 (12/10) User Manual
Page 26

26
Desk Control Terminals
The.Friedrich.PD.model.PTAC.has.built-in.provisions.for.connection.to.an.
external.switch.to.control.power.to.the.unit..The.switch.can.be.a.central.
desk.control.system.or.even.a.normally.open.door.switch.
For.desk.control.operation.connect.one.side.of.the.switch.to.the.D1.terminal.
and.the.other.to.the.D2.terminal.(See.Figure.31,.Page.23)..Whenever.the.
switch.closes.the.unit.operation.will.stop.
NOTE:.
The.desk.control.system.and.switches.must.be.field.supplied.
Energy Management
Sometimes.known.as.Front.Desk.Control,.an.input.is.provided.so.that.the.
unit.can.be.manually.disabled.from.a.remote.location...If.the.unit.detects.
24Vac.on.this.input,.it.will.automatically.turn.itself.off...If.no.voltage.is.
detected.on.the.input.,.the.unit.will.run.normally.
NOTE:..
It.is.the.installer's.responsibility.to.ensure.that.all.control.wiring.
connections.are.made.in.accordance.with.the.installation.
instructions..Improper.connection.of.the.thermostat.control.
wiring.and/or.tampering.with.the.unit's.internal.wiring.can.
void.the.equipment.warranty..Other.manufacturer's.PTACs.
and.even.older.Friedrich.models.may.have.different.control.
wire.connections...Questions.concerning.proper.connections.
to.the.unit.should.be.directed.to.Friedrich.
WARNING
Electrical Shock Hazard
Turn off electrical power before service
or installation.
ALL electrical connections and wiring
MUST be installed by a qualified
electrician and conform to the National
Code and all local codes which have
jurisdiction.
Improper connection of the thermostat
control wiring and/or tampering with the
units internal wiring may result in property
damage, personal injury or death.
- 7,200 BTU Packaged Terminal Air Conditioner Warranty 7,200 BTU Packaged Terminal Air Conditioner Installation and Operation Manual ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty A-SERIES 24,000 BTU/h 9 HEAT PUMPS 7,200 BTU Packaged Terminal Air Conditioner Product Profile ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty Guide ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Installation Guide ZoneAire Series Electric Heat Packed Terminal Air Conditioner Installation Manual ZoneAire Series 14,500 BTU Smart Packaged Terminal Air Conditioner Installation Guide 12,000 BTU FreshAire® Package Terminal Air Conditioner Installation Manual