FRP030
°F vs. °C Display
The.unit.is.factory.configured.to.display.all.temperatures.in.degrees.
Fahrenheit.(°.F)..To.switch.to.degrees.Celsius.press.the.‘Fan.Only’.and.
‘Low.Fan’.buttons.simultaneously.for.three.seconds..The.display.will.show.
a.‘C’.as.acknowledgement.of.the.change...To.revert.back.to.°.F.press.the.
‘Fan.Only’.and.‘Low.Fan’.buttons.simultaneously.for.three.seconds..The.
display.will.show.an.‘F’.as.acknowledgement.of.the.change.
Cooling Mode
Pressing.the.‘Cool’.button.while.the.unit.is.in.any.mode,.including.off,.
will.put.the.unit.into.cooling.mode..Adjust.the.temperature.readout.to.the.
desired.room.temperature.and.the.unit.will.cycle.the.compressor.on.and.
off.to.maintain.a.comfortable.room..The.compressor.will.come.on.anytime.
that.the.room.temperature.is.1.8°.F.above.the.desired.temperature..The.
fan.operation.is.dependent.on.the.fan.mode.selected,.either.continuous.
or.cycling...See.Fan.Mode.for.fan.cycle.control.
Heating Mode
Pressing.the.‘Heat’.button.while.the.unit.is.in.any.mode,.including.off,.will.
put.the.unit.into.heating.mode.
Heat Pump Models (PDH)
When.the.‘Heat’.button.is.pressed.initially.the.unit.will.energize.the.electric.
resistance.heat.to.quickly.bring.the.room.to.the.set.temperature...When.the.
desired.room.temperature.falls.1.8°.F.below.the.desired.set.temperature.the.
unit.will.cycle.the.compressor.on.and.operate.as.a.heat.pump.to.maintain.
the.room.temperature.while.running.more.efficiently.than.resistance.heat.
only.models...If.the.room.temperature.should.fall.more.than.5°.F.from.the.
set.temperature.the.unit.will.run.the.resistance.heater...The.fan.operation.
is.dependent.on.the.fan.mode.selected,.either.continuous.or.cycling..Dip.
switch.3.controls.the.fan.mode,.see.page.23.for.setting...
When.the.outdoor.coil.temperature.falls.below.30°.F.for.more.than.2.min-
utes.the.unit.will.operate.the.resistance.heaters.and.not.the.compressor...
When.the.outdoor.coil.temperature.reaches.45°.F.the.compressor.will.be.
allowed.to.operate.again.
Heat/Cool Models (PDE)
After.pressing.the.‘Heat’.button,.adjust.the.temperature.readout.to.the.
desired.room.temperature.and.the.unit.will.cycle.the.resistance.heat.on.
and.off.to.maintain.a.comfortable.room..The.heater.will.come.on.anytime.
that.the.room.temperature.is.1.8°.F.below.the.desired.temperature..The.
fan.operation.is.dependent.on.the.fan.mode.selected,.either.continuous.
or.cycling..Dip.switch.3.controls.the.fan.mode,.see.page.23.for.setting.
Emergency Heat Operation
In.the.event.of.a.compressor.failure.in.heat.pump.mode.the.compressor.may.
be.locked.out.to.provide.heat.through.the.resistance.heater..This.feature.
ensures.that.even.in.the.unlikely.event.of.a.compressor.failure.the.room.
temperature.can.be.maintained.until.the.compressor.can.be.serviced..Dip.
switch.1.controls.the.emergency.heat.setting,.see.page.23.
Fan Mode
All.units.are.shipped.with.fan.mode.set.to.continuous.for.cooling.and.cycle.
for.heating.
Fan Only Mode
Pressing.the.‘Fan’.button.will.run.the.fan.to.allow.for.air.circulation.in.the.
room.without.operating.the.compressor.or.heater.regardless.of.the.room.
or.set.temperature..The.fan.speed.selection.is.made.by.pressing.either.
the.‘High.Fan’,.‘Med.Fan’.or.‘Low.Fan’.button.
Cycle/Continuous
The.owner.may.choose.between.fan.cycling.or.fan.continuous.mode.based.
on.property.preference.(Note:.Even.heat.monitoring.and.quiet.start/stop.
fan.delay.only.operate.in.fan.cycle.mode)..Fan.continuous.mode.is.used.
to.keep.constant.airflow.circulation.in.the.room.during.all.times.the.unit.is.
‘ON’..Fan.cycle.will.conserve.energy.by.only.operating.the.fan.while.the.
compressor.or.electric.heater.is.operating..Dip.switch.3-4.controls.the.fan.
mode,.see.page.23.for.setting.
Digital Control Operation
Figure 32
Digital Control Panel
- 7,200 BTU Packaged Terminal Air Conditioner Warranty 7,200 BTU Packaged Terminal Air Conditioner Installation and Operation Manual ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty A-SERIES 24,000 BTU/h 9 HEAT PUMPS 7,200 BTU Packaged Terminal Air Conditioner Product Profile ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Warranty Guide ZoneAire Series 42 Inch Packaged Terminal Air Conditioner Installation Guide ZoneAire Series Electric Heat Packed Terminal Air Conditioner Installation Manual ZoneAire Series 14,500 BTU Smart Packaged Terminal Air Conditioner Installation Guide 12,000 BTU FreshAire® Package Terminal Air Conditioner Installation Manual