Using FortiSwitch-5003A and FortiSwitch-5003 boards for backplane communication

FortiGate-5050 hardware procedures

FortiGate-5050-R Chassis Guide

26

01-30000-87717-20090108

http://docs.fortinet.com/

Feedback

See the following documents for information about installing and removing the following
FortiGate-5000 series and FortiSwitch-5000 series modules:
FortiGate-5001A

FortiGate-5001A Security System Guide

FortiGate-5005FA2:

FortiGate-5005FA2 Security System Guide

FortiGate-5001SX:

FortiGate-5001SX Security System Guide

FortiGate-5001FA2:

FortiGate-5001FA2 Security System Guide

FortiSwitch-5003A

FortiSwitch-5003A System Guide

FortiGate-RTM-XB2

FortiGate-RTM-XB2 System Guide

FortiSwitch-5003

FortiSwitch-5003 System Guide

Using FortiSwitch-5003A and FortiSwitch-5003 boards for
backplane communication

FortiSwitch-5003A boards installed in a FortiGate-5050 chassis in slot 1 or slot 2 provide
fabric backplane switching for all of the FortiGate-5000 series boards installed in chassis
slots 3 and above. Fabric backplane switching is most often used for data communication
between FortiGate-5000 series boards in a chassis, between chassis, and between the
chassis and the network.
FortiSwitch-5003A and 5003 boards installed in a FortiGate-5050 chassis in slot 1 or slot 2
provide base backplane switching for all of the FortiGate-5000 series boards installed in
chassis slots 3 and above. Base backplane switching is usually used for HA heartbeat
communication between FortiGate-5000 series boards in HA clusters.
For complete information about using the FortiSwitch-5003A and 5003 for backplane
communications (including the FortiSwitch-5003A CLI reference), see the

FortiSwitch-5003A and 5003 Fabric and Base Backplane Communication Guide

.

Caution: FortiGate-5000 series and FortiSwitch-5000 series modules must be protected
from static discharge and physical shock. Only handle or work with FortiGate-5000 series
and FortiSwitch-5000 series modules at a static-free workstation. Always wear a grounded
electrostatic discharge (ESD) preventive wrist or ankle strap when handling FortiGate-5000
series or FortiSwitch-5000 series modules.

Caution: Do not operate the FortiGate-5050 chassis with open slots on the front panel or
rear panel. For optimum cooling performance and safety, front panel slots must contain a
FortiGate-5000 series module or an air baffle slot filler and rear panel slots must either be
covered or must contain a rear transition module or slot filler. As well the removable PEM
terminal block covers must be installed over the power connectors on the back of the
chassis.