beautypg.com

Fortinet FortiGate 5050-R User Manual

Page 13

background image

FortiGate-5050 chassis

Shelf manager command line interface (CLI)

FortiGate-5050-R Chassis Guide
01-30000-87717-20090108

13

http://docs.fortinet.com/

Feedback

Figure 7: Connecting to a shelf manager serial port

To connect to the shelf manager CLI using a shelf alarm panel serial port

1 Connect the Fortinet console cable to the shelf alarm panel Serial 1 or Serial 2 port

(see

Figure 7

).

2 Connect the Fortinet console cable to your PC or other device RS-232 console port.
3 Start a terminal emulation program (for example, HyperTerminal) on the management

computer. Use these settings:

4 Press enter to connect to the CLI.
5 At the login prompt enter the shelf manager user name and password.

The default user name is root with no password.
When you log into the shelf manager CLI you are logging into a Linux shell as root. You
can begin entering commands at the # prompt:
#

To add or change the shelf manager root account password

For enhanced security you should use the following steps to add a password for the shelf
manager root account.
1 At the # prompt enter the following Linux command to add a password for the root

account:
# passwd

Baud Rate (bps)

9600

Data bits

8

Parity

None

Stop bits

1

Flow Control

None

5050SAP

SERIAL

1

SERIAL

2

ALARM

SERIAL1 (Primary

Shelf Manager)

FortiGate-5050 Shelf Alarm Panel

SERIAL2 (Secondary

Shelf Manager)

Fortinet

RJ-45 to

9-pin

Console

Cable

To PC

RS-232

Console

Port