Redundant fortigate-5050 power supplies, Redundant fortigate-5053 power converter trays, Figure 12 – Fortinet FortiGate 5050-R User Manual
Page 20
Connecting the FortiGate-5050 chassis to AC power using the FortiGate-5053 power converter tray
FortiGate-5050-R Chassis Guide
20
01-30000-87717-20090108
Figure 12: Non-redundant power for all FortiGate-5050 chassis slots
Redundant FortiGate-5050 power supplies
You can supply redundant power to a FortiGate-5050 chassis by adding a third
FortiGate-5020/5050 power supply to the FortiGate-5053 power converter tray
(see
Figure 13
). If one of the FortiGate-5020/5050 power supplies in the FortiGate-5053
power converter tray fails, the third power supply takes its place without a power
interruption.
Figure 13: 2 + 1 redundant FortiGate-5020/5050 power supplies
Redundant FortiGate-5053 power converter trays
A single FortiGate-5053 power converter tray is usually only connected to one
FortiGate-5050 power input connector. If this power input connector or FortiGate-5053
power converter tray fails or is disconnected the FortiGate-5050 chassis will loose power.
You can supply redundant power to the entire FortiGate-5050 chassis by adding a second
FortiGate-5053 power converter containing two or three FortiGate-5020/5050 power
supplies and connected this FortiGate-5053 power converter tray to the second
FortiGate-5050 power input connector.
Slot 1
Slot 2
Slot 3
1 FortiGate-5053
power convertor tray
2 FortiGate-5020/5050
power supplies
2 x 800W = 1600W
1 FortiGate-5050
chassis
1
2
2
3
4
5
SMC
1
SMC
POWER
5050SAP
SERIAL
1
SERIAL
2
ALARM
10/100
link/Act
ETH0 Service
RESET
ST
AT
US
Hot Swap
link/Act
ETH0
ETH1
10/100
5000SM
10/100
link/Act
ETH0 Service
RESET
ST
AT
US
Hot Swap
link/Act
ETH0
ETH1
10/100
5000SM
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
E2
OK
CLK
INT
EXT
FL
T
HOT SW
AP
RESET
FL
T
CONSOLE
E T H O
R S 2 3 2
Z R E 0
Z R E 1
Z R E 2
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
E2
OK
CLK
INT
EXT
FL
T
HOT SW
AP
RESET
FL
T
CONSOLE
E T H O
R S 2 3 2
Z R E 0
Z R E 1
Z R E 2
PWR
STA IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC
PWR
STA IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC
PWR
STA IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC
Slot 1
Slot 2
Slot 3
1 FortiGate-5053
power convertor tray
3 FortiGate-5020/5050
power supplies
2 x 800W = 1600W
2 + 1 redundancy
1 FortiGate-5050
chassis
1
2
2
3
4
5
SMC
1
SMC
POWER
5050SAP
SERIAL
1
SERIAL
2
ALARM
10/100
link/Act
ETH0 Service
RESET
ST
ATUS
Hot Swap
link/Act
ETH0
ETH1
10/100
5000SM
10/100
link/Act
ETH0 Service
RESET
ST
ATUS
Hot Swap
link/Act
ETH0
ETH1
10/100
5000SM
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
E2
OK
CLK
INT
EXT
FL
T
HOT SW
AP
RESET
FL
T
CONSOLE
E T H O
R S 2 3 2
Z R E 0
Z R E 1
Z R E 2
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
E2
OK
CLK
INT
EXT
FL
T
HOT SW
AP
RESET
FL
T
CONSOLE
E T H O
R S 2 3 2
Z R E 0
Z R E 1
Z R E 2
PWR
STA IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC
PWR
STA IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC
PWR
STA IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC