B.3.3 using the showstatus command, B.3.3, Using the showstatus command – FUJITSU M3000 User Manual
Page 72

B-8
SPARC Enterprise M3000 Server Installation Guide • January 2009
Example of showlogs output
B.3.3
Using the showstatus Command
The showstatus command displays information concerning a faulty or degraded
FRU and the FRU that is one layer above the faulty or degraded FRU in the server.
The displayed FRU information includes an asterisk (*), which indicates the location
of the problem, and any of the following states after "Status:":
■
Faulted: The component is faulty and is not operating.
■
Degraded: The component is operating. However, either an error has been
detected or the component is faulty. As a result, the component might be
operating with reduced functionality or performance.
■
Deconfigured: As a result of another component's faulted or degraded status, the
component is not operating. (The component itself is not faulted or degraded.)
■
Maintenance: The component is under maintenance. A deletefru (8),
replacefru
(8), or addfru (8) operation is currently underway.
Example of showstatus output
XSCF> showlogs error
Date: Jun 17 13:46:31 JST 2008 Code: 60000000-cd01c701-0164010100000000
Status: Warning Occurred: Jun 17 13:46:31.158 JST 2008
FRU: /OPNL,/FANBP_B
Msg: TWI access error
Date: Jun 17 13:41:46 JST 2008 Code: 80002080-7801c201-0130000000000000
Status: Alarm Occurred: Jun 17 13:41:44.861 JST 2008
FRU: /MBU_A,*
Msg: Board control error (MBC link error)
Date: Jun 17 11:05:32 JST 2008 Code: 80000000-c3ff0000-0173000600000000
Status: Alarm Occurred: Jun 17 11:05:32.522 JST 2008
FRU: /PSU#1
Msg: PSU shortage
XSCF>
XSCF> showstatus
FANBP_B Status:Normal;
* FAN_A#0 Status:Faulted;
XSCF>