ITEM

PART #

COMPONENT

*

816-0554

Cover, Molded Plastic Blower Motor (fits left- or right-hand blowers)

*

809-0938

Screw, 10-32 X Philips Truss Head (secures Blower Motor Cover to motor)

*

826-1383

Washer, ¼-inch Flat (for mounting blower to plenum) (Pkg. of 5)

*

826-1372

Nut, ¼-20 Hex (for mounting blowers to plenum) (Pkg. of 10)

*

KIT-0155SP

High Altitude Blower Kit (required above 5000 Ft, 1525 M)

*

Not illustrated.

NOTES:

Items 5, 6, and 7 are components of Items 3 and 4. In CE units, they replace the rotating air shut-

ter that is standard on 230V Blowers 106-3000SP and 106-3001SP (Items 3 and 4).

Blower Motor Cover P/N 816-0054 and Screw P/N 809-0938 are components of Items 1 through 4.

For Full Vat units, use Blower Assembly 106-2994SP (Non-CE) or 106-3000SP (CE). (Left Assembly.)

Some earlier CE units were built with blowers having housings 1.54 inches (3.91 cm) wide. Current
production CE-units are built with blowers having housings 2.71 inches (6.88 cm) wide. When order-
ing replacements for CE units, the width of the blower housing must be verified to ensure the correct
blower is provided.

CE units built before June 1999 were equipped with a blower shield that completely covered the
blower assemblies. This shield is no longer required and may be removed. The component parts of
the shield are no longer available for replacement.