Fortinet FortiGate 5140-R User Manual
Page 13
FortiGate-5140 chassis
Shelf manager command line interface (CLI)
FortiGate-5140-R Chassis Guide
01-30000-87705-20090108
13
Figure 7: Connecting to a shelf manager serial port
To connect to the shelf manager CLI using a shelf alarm panel serial port
1 Connect the Fortinet console cable to the shelf alarm panel Serial 1 or Serial 2 port
(see
Figure 7
).
2 Connect the Fortinet console cable to your PC or other device RS-232 console port.
3 Start a terminal emulation program (for example, HyperTerminal) on the management
computer. Use these settings:
4 Press enter to connect to the CLI.
5 At the login prompt enter the shelf manager user name and password.
The default user name is root with no password.
When you log into the shelf manager CLI you are logging into a Linux shell as root. You
can begin entering commands at the # prompt:
#
To add or change the shelf manager root account password
For enhanced security you should use the following steps to add a password for the shelf
manager root account.
1 At the # prompt enter the following Linux command to add a password for the root
account:
# passwd
Baud Rate (bps)
9600
Data bits
8
Parity
None
Stop bits
1
Flow Control
None
CRITICAL
RESET
MAJOR MINOR USER1 USER2 USER3
5140SAP
SERIAL 1
SERIAL 2
ALARM
SERIAL 2 (Secondary
Shelf Manager)
SERIAL1 (Primary
Shelf Manager)
FortiGate-5140 Shelf Alarm Panel
Fortinet
RJ-45 to
9-pin
Console
Cable
To PC
RS-232
Console
Port