Shelf Manager fan and power control

The FortiGate-5140 shelf managers monitor the internal temperature of the
FortiGate-5140 chassis and adjust the operating speed of the FortiGate-5140 chassis
cooling fans as required.
When the chassis is first powered on all cooling fans run at full speed. Once the shelf
manager is up and running, the shelf manager reduces cooling fan speeds to maintain an
optimum temperature in the chassis. If shelf managers are not installed or not operating
correctly the FortiGate-5140 chassis cooling fans always operate at full speed.

FortiGate-5140 shelf alarm panel

The FortiGate-5140 shelf alarm panel (SAP), located at the top of the FortiGate-5140 front
panel, provides LED indicators of FortiGate-5140 alarms, a telco alarm connector, an
alarm LED reset button, and console access to the FortiGate-5140 shelf managers. The
LED alarm indicators include critical, major, and minor alarms as well as three user
defined alarms.
The alarm LED reset button (RESET) on the shelf alarm panel activates the Alarm Cutoff
(ACO) state. When ACO is activated, the active alarm LEDs blink and all of the alarm
relays are deactivated.

Figure 4: FortiGate-5140 shelf alarm panel front panel

Table 3: FortiGate-5140 shelf alarm panel LEDs

LED

State

Description

CRITICAL

Off

Normal operation.

Red

Indicates a critical alarm.

Blinking

Red

Alarm cutoff (ACO) activated by pressing the alarm LED reset button.

MAJOR

Off

Normal operation.

Red

Indicates a major alarm.

Blinking

Red

Alarm cutoff (ACO) activated by pressing the alarm LED reset button.

MINOR

Off

Normal operation.

Amber

Indicates a minor alarm.

Blinking

Amber

Alarm cutoff (ACO) activated by pressing the alarm LED reset button.

USER1
USER2
USER3

Off

Normal operation

Amber

Indicates a user-definable alarm.

Blinking

Amber

Alarm cutoff (ACO) activated by pressing the alarm LED reset button.

CRITI

CAL

RESET

MAJOR MINOR USER1 USER2 USER3

5140SAP

SERIAL 1

SERIAL 2

ALARM

Retention

Screw

Retention

Screw

Telco Alarm

Interface

Alarm

LED Reset

Button

Minor Alarm (Amber)

Major Alarm (Red)

Critical Alarm (Red)

User 1 Alarm (Amber)
User 2 Alarm (Amber)
User 3 Alarm (Amber)

SERIAL 1 (Primary

Shelf Manager)

SERIAL 2 (Secondary

Shelf Manager)