FUJITSU Disk Storage System DX60 User Manual
Page 100

Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
100
Copyright 2012 FUJITSU LIMITED
P3AM-5512-03ENZ0
●
When the event type is "M"
The following messages are sent when an event that requires maintenance occurs:
P DASSdd00
6
DA00dd00 2
DE Exhaust temperature DE#dd Fatal
These messages
are notified when
"Module was
broken" is enabled
for Error Severity
Level in the event
notification setting.
They are not notified
during maintenance
operations.
CE exhaust temperature error or DE exhaust
temperature error (fatal error) is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
P DASSdd00
2
DA00dd00 -
DE Exhaust temperature sensor DE#dd Fault
CE exhaust temperature error or DE exhaust
temperature error (sensor failure) is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
P DBSSdd00
2
DB00dd00 -
DE Intake temperature sensor DE#dd Fault
CE intake temperature error or DE intake
temperature error (sensor failure) is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
Event type
and event
code
SNMP Trap
Upper: Message
Remarks
Trap
No.
Trap
Maintenance
Info
Lower: Description
M 21810xxx
7
21810xxx
RAID Group#0xxx recovered end of Rebuild processing
These messages
are notified when
"RAID Degradation
Event" is enabled
for Warning Level in
the event
notification setting.
They are not notified
during maintenance
operations.
Rebuilding to a hot spare or a replaced disk is complete,
but Bad Data (data lost identifier) exists.
xxx: RAID group number
M E005nxxx
7
E005xxxx
WRITE BAD DATA
Writing of Bad Data (data lost identifier) occurs.
xxx: RAID group number
M E10300xx
7
E10300xx
PINNED DATA was created CM#m
These messages
are notified when
the relevant event
occurs.
Pinned Data occurs.
xx: CM module ID in which Pinned Data occurred
m: CM number in which Pinned Data occurred
M E2070001
7
E2070001
NOT READY(01:Configuration Error)
The device is in Not Ready status.
Shipment settings (model setting) and configurations are
not applied.
M E2070002
7
E2070002
NOT READY(02:CM F/W Version Error)
The device is in Not Ready status.
Firmware version for the CM is not correct.
M E2070004
7
E2070004
NOT READY(04:Restore Fail)
The device is in Not Ready status.
Backup is successfully complete, but cannot perform the
restoration.
Event type
and event
code
SNMP Trap
Upper: Message
Remarks
Trap
No.
TrapItemID
Trap
Sensor
Info
Lower: Description