01-30000-76602-20080606

Front panel LEDs and connectors

FortiGate-5001FA2-LENC security system

• Mounting hardware
• LED status indicators

The FortiGate-5001FA2-LENC board comes supplied with four optical or four
copper SFP transceivers. Before you can connect FortiGate-5001FA2-LENC
interfaces 1 to 4, you must insert the SFP transceivers into the
FortiGate-5001FA2-LENC front panel cage slots numbered 1 to 4.

The FortiGate-5001FA2-LENC board ships with two RAM DIMMs installed on the
FortiGate-5001FA2-LENC circuit board. You should confirm that the RAM DIMMs
are installed correctly before inserting the FortiGate-5001FA2-LENC board into a
chassis.

Front panel LEDs and connectors

From the FortiGate-5001FA2-LENC font panel you can view the status of the front
panel LEDs to verify that the board is functioning normally. You also connect the
FortiGate-5001FA2-LENC board to your network through the front panel ethernet
connectors. The front panel also includes the RS-232 console port for connecting
to the FortiOS CLI and a USB port. The USB port can be used with a Fortinet USB
key. For information about using the FortiUSB key, see the

FortiGate-5000 Series

Firmware and FortiUSB Guide

.

LEDs

Table 1

lists and describes the FortiGate-5001FA2-LENC board LEDs.

Table 1: FortiGate-5001FA2-LENC board LEDs

LED

State

Description

PWR

Green

The FortiGate-50012FA2 board is powered on.

ACC

Off or

Flashing

red

The ACC LED flashes red when the

FortiGate-5001FA2-LENC board accesses the FortiOS flash

disk. The FortiOS flash disk stores the current FortiOS

firmware build and configuration files. The system accesses

the flash disk when starting up, during a firmware upgrade, or

when an administrator is using the CLI or GUI to change the

FortiOS configuration. Under normal operating conditions this

LED flashes occasionally, but is mostly off.

STA

Green

Normal operation.

Red

The FortiGate-5001FA2-LENC is booting or a fault condition

exists.

IPM

Blue

The FortiGate-5001FA2-LENC is ready to be hot-swapped

(removed from the chassis). If the IPM light is blue and no

other LEDs are lit the FortiGate-5001FA2-LENC board has

lost power, possibly because of a loose or incorrectly aligned

left handle. See

“Inserting a FortiGate-5001FA2-LENC board

into a chassis” on page 13

for more information.

Flashing

Blue

The FortiGate-5001FA2-LENC is changing from hot swap to

running mode or from running mode to hot swap.

Off

Normal operation. The FortiGate-5001FA2-LENC board is in

contact with the chassis backplane.

1, 2, 3, 4

Green

The correct cable is connected to the gigabit SFP interface.

Flashing

Network activity at the gigabit SFP interface.