FortiGate-5001FA2-LENC base backplane data communication

FortiGate-5001FA2-LENC Security System Guide
01-30000-76602-20080606

31

In a FortiGate-5140 or FortiGate-5050 chassis, FortiGate-5001FA2-LENC base
backplane communication requires one or two FortiSwitch-5003 boards.
A FortiSwitch-5003 board installed in chassis slot 1 provides communication on
the port9 interface. A FortiSwitch-5003 board installed in chassis slot 2 provides
communication on the port10 interface. The FortiGate-5020 chassis supports
base backplane data communication for both interfaces with no additions or
changes to the chassis.

For details and configuration examples of FortiGate-5001FA2-LENC base
backplane communication using the FortiSwitch-5003 board, see the

FortiGate-

5000 Base Backplane Communication Guide

.

To enable base backplane data communication from the
FortiGate-5001FA2-LENC web-based manager

From the FortiGate-5001FA2-LENC web-based manager use the following steps
to enable base backplane data communication.

1

Go to System > Network > Interface.

2

Select Show backplane interfaces.

The port9 and port10 backplane interfaces now appear in the Interface list.

Figure 9: FortiGate-5001FA2-LENC interface list with backplane interfaces enabled

To enable base backplane data communication from the
FortiGate-5001FA2-LENC CLI

From the FortiGate-5001FA2-LENC board CLI you can use the following steps to
enable base backplane data communication.

1

Enter the following command to show the backplane interfaces:

config system global

set show-backplane-intf enable

end