FUJITSU MHV2120AT User Manual
Page 31

1.3 Power Requirements
C141-E218
1-7
(4) Current Requirements and Power Dissipation
Table 1.3 lists the current and power dissipation (typical).
Table 1.3 Current and power dissipation
Typical RMS Current
Typical Power (*3)
Spin up (*1)
0.9 A
4.5 W
Idle
100 mA
0.5 W
R/W (on track) (*2)
320 mA
1.6 W
Seek (*5)
380 mA
1.9 W
Standby
40 mA
0.2 W
Sleep
20 mA
0.1 W
Energy
Efficiency (*4)
—
0.004 W/GB (rank E / MHV2120AT)
0.005 W/GB (rank E / MHV2100AT)
0.006 W/GB (rank E / MHV2080AT)
0.008 W/GB (rank E / MHV2060AT)
0.013 W/GB (rank D / MHV2040AT)
*1
Maximum current at starting spindle motor.
*2
Current and power level when the operation (command) that accompanies a
transfer of 63 sectors is executed 3 times in 100 ms
*3
Power requirements reflect typical values for +5 V power.
*4
Energy efficiency based on the Law concerning the Rational Use of Energy
indicates the value obtained by dividing power consumption by the storage
capacity. (Japan only)
*5
The seek average current is specified based on three operations per 100
msec.