beautypg.com

FUJITSU MHV2120AT User Manual

Page 188

background image

Interface

5-112

C141-E218

(39) READ NATIVE MAX ADDRESS EXT (X’27’): Option (customizing)

Description

This command is used to assign the highest address that the device can initially
set with the SET MAX ADDRESS EXT command. The maximum address is
displayed in the CH, CL, SN registers of the device control register with HOB bit
= 0, 1.

Error reporting conditions

This command is issued with LBA = 0. (ST = 51h, ER= 04h: Aborted command)

At command issuance (I/O registers setting contents)

1F7

h

(CM) 0 0 1 0 0 1 1 1

1F6

h

(DH) 1 L 1 DV

xx

1F5

h

(CH) P

1F5

h

(CH) C

1F4

h

(CL) P

1F4

h

(CL) C

1F3

h

(SN) P

1F3

h

(SN) C

1F2

h

(SC) P

1F2

h

(SC) C

1F1

h

(FR) P

1F1

h

(FR) C

xx

xx

xx

xx

xx

xx

xx

xx

xx

xx

C: Current
P: Previous

At command completion (I/O registers contents to be read)

1F7

h

(ST) Status

information

1F6

h

(DH) 1 L 1 DV

xx

1F5

h

(CH) 1

1F5

h

(CH) 0

1F4

h

(CL) 1

1F4

h

(CL) 0

1F3

h

(SN) 1

1F3

h

(SN) 0

1F2

h

(SC) 1

1F2

h

(SC) 0

1F1

h

(ER)

Native max address LBA (47-40)

Native max address LBA (23-16)

Native max address LBA (39-32)

Native max address LBA (15-8)

Native max address LBA (31-24)

Native max address LBA (7-0)

xx

xx

Error information

0: HOB=0
1: HOB=1

This manual is related to the following products: